Foxboro DNBI Control Module
Electronics Housing and Housing Covers
Housing has two compartments to separate the
electronics from the field connections. The housing
and covers are made from low copper (0.6%
maximum) die-cast aluminum alloy with an epoxy
finish, or from 316 ss. Buna-N O-ring seals are used
to seal the threaded housing covers, housing neck,
and terminal block.
Electrical Terminations
Field wires enter through 1/2 NPT, PG 13.5. or M20
threaded entrances, as specified, on either side of
the electronics housing. Wires terminate under
screw terminals and washers on terminal block in
the field terminal compartment as shown in Figure .
Unused threaded field wire entrance is plugged to
insure moisture and RFI/EMI protection.
Three- or Four-Wire Connections
Transmitter is supplied with a 4-wire terminal block,
with the two negative terminals connected internally.
This means that the transmitter can be wired with
either three wires for wiring economy, or four wires
for maximum accuracy. For relatively short wiring
runs having low resistance, 3-wire connections can
be used to minimize wiring costs. However, a voltage
drop in the common lead carrying the power supply
current will cause an error in the 1 to 5 V dc signal.
For wiring runs with high resistance due to long
lengths (or other reasons), or for maximum
accuracy, a 4-wire connection may be used to
provide input-output isolation. With 4-wire
configurations, voltage drop in the power supply loop
will have minimal effect on measurement.
Configuration and Calibration Data, and
Electronic Upgradeability
All factory characterization data, and user
configuration and calibration data are stored in the
sensor. This means that the electronics module may
be replaced, with one of like type, without the need
for reconfiguration or recalibration. Although module
replacement can affect accuracy up to 0.20% of
span, this error can be removed by an mA trim
without application of pressure.
Changing module types (from one protocol to
another) may require reconfiguration and
recalibration, as well as a different terminal block,
but all factory characterization data is retained.
Optional External Zero Adjustment
An external pushbutton (Figure 3) mechanism is
isolated from the electronics compartment and
magnetically activates an internal reed switch
through the housing. This eliminates a potential leak
path for moisture or contaminants to get into the
electronics compartment. This zero adjustment can
be disabled by a configuration selection.
Optional Transmitter Mounting Bracket Sets
Numerous mounting bracket set options are offered
to accommodate almost any mounting configuration
required. See “DIMENSIONS – NOMINAL” on
page 36.
| PRT | PSA300R-81 |
| PTM | PSMU-350-3 |
| PULS | SLA8.100 |
| QSI | QTERM-K65 |
| R-2528Z | R-2528Z |
| RADISYS | EPC-16 |
| RADISYS | EPC-5 W/ EXM-13 |
| RADISYS | SBC486DX66 |
| RAMIX | PMC008A 700502 |
| RAMIX | PMC237C-008EMI |
| RAMIX | PMC661J |
| RAMIX | PMC676TX |
| RAYCHEM | EMDR |
Optional Custom Configuration (Option -C2)
For the transmitter to be custom configured by the
factory, the user must fill out a data form. If this
option is not selected, a standard default
configuration will be provided; for example:
Features
The key features of the Compact FBM242 module are listed below:
16 discrete outputs
Supports discrete output signals for the following voltages
– 15 to 60 VDC
– 120 VAC/125 VDC
– 240 VAC
Each output is galvanically isolated; group-isolated when used with external excitation.
Compact and rugged, suitable for enclosures in Class G3 (harsh) environments
Executes discrete I/O or ladder logic programs, configurable with the following options:
Input Filter Time, Fail Safe Configuration, Fail Safe Fallback, Continuous or Instantaneous Outputs
Various terminal assemblies (TAs) that include the following
– Current limiting devices
– Fuses
– Relay outputs with external power supply, fuses and distribution
– Solid-state outputs
– Redundant power distribution
The FCP280 also supports the following functions:
– Setting and reading FCP280 beacons via panel pushbuttons
– Function Block Alarm Enhancement:
Re-alarm on alarm priority change
Re-alarm on configurable time-delayed dead zones and suppress alarms based on time
– Optional UTC external time synchronisation
– Improved controller performance
– The optional self-hosted mode allows the FCP280 to boot up and run,
executing configured control schemes using checkpoint files stored in flash memory.