ALSTOM

Alstom L54E2901TW00 – Printed Circuit Board

Update Mode Button Functions

Delete PTC Files – Deletes PTC Mapping and Configuration Filesfrom CI-2

Erase CI Flash – Erases CI Flash; PTC, SNMP and any Application Filees

Format Program Files – Deletes the non-volatile file file upload area

Format Log Flash – All Log files are deleted. System, Data, Configetc…

Erase BP – Deletes all parameters from backplane. (All Setup info)

Format Site Flash* – Deletes Vital and non-vital configuration settings, SSNMP

configuration, Application and all PTC Files from the Site Flash

Erase App* – Deletes Application files from the Site Flash

Erase Configuration* – Deletes Vital and non-vital configuration seettings and

SNMP configuration from the Site Flash

Erase PTC Files* – Deletes all PTC files from Site Flash

Download Site Flash* – Downloads all the contents of the SiteFlash (Boot)

Version 5.18 or newer and Executive version 7.27 (Crossing)6.39

(Interlocking), 8.29 (Combined) or newer is required for this optionn). *Note

Available only if Site Flash is enabled. Boot Version 5.18 and Executlive

version 7.27 (Crossing), 6.39 (Interlocking),

8.29 (Combined) and newer will allow chassis backup and restore.

Ethernet Executive Upload Procedure (Recommended)

Note: It isrecommended the configuration is saved before proceeding!

Enter Update Mode as described in the Update Mode section

Select ‘Executive/Boot’ from the ‘Upload New’ drop-down, then

browse and select the Executive software file to be uploaded

If the Executive file is successfully uploaded, “File Successfully

Uploaded” will appear in the dialog box

Verify the correct build and CRC information is displayed.

To apply the Executive file, click on “Apply Executive/Boot”

When the Executive file is applied successfully, “File Applied

Successfully”, will be displayed

Activate the Executive by pressing the Activate button and following the

instructions on the Web UI. Once activated, reboot the VPM-3 by either

pressing the Reset button or cycling power on the chassis.

Ethernet Application Flash Upload Procedure

Diagnostic Telnet Connection

1. Connect to a VPM-3 with an RJ45 Cable (crossover or straight)

2. Enable the Telnet Interface through the CDU-1. CDU-2 or Web GUI

3. Using a Terminal program (Hyper Terminal, ProComm, etc) connecttothe IP

address for the VPM-3 Port connected to.

Enter username and password for the Telnet Interface.

metso ND9102HN
KEBA SC102
HONEYWELL 620-0041
HONEYWELL 620-1633
ABB UNS0874
ABB UNS0874
HIMA PS1000/230
HIMA Z7128/6217/C5/ITI/R
HIMA F7130A
HIMA F8653X
HONEYWELL 05701-A-0302
HONEYWELL 620-0041
HONEYWELL 620-1633
GE IC754CGL06CTD
ABB 3BHE022287R0001
GE MCU2A02V2-4 1SCA022657R9090
Foxboro FCM10Ef P0916CP

Default login: admin.

Default password: telnet

Diagnostic Serial Connection

1. Connect to CIO-1A with 9-Pin null modem cable. CIO-1AA can be addedto

any ELX unit with no other changes.

Open terminal session configured as follows

Baud*:57600

Parity: None

Data Bits: 8

Stop Bits: 1

Flow control: None

Terminal Emulation:VT100 or ANSI BBS

Data Transfer Protocol: Z Modem

*57600 is the default setting, but can be modified

3. Type’?’ or ‘help’to see the boot menu shown below