ALSTOM PIB701 MV7306P16 Power Cell Unit
Locate the 96-way connector on the PROFIBUS board into the
socket (A) at the back of the control board, as shown in
Figure 3-9. Secure the front panel to the chassis using the two
M4 screws removed at step 3.
Attach the label (F) if supplied, and fit dust covers (B)to any
PROFIBUS connector that will be exposed for a lengthy period,
see Figure 3-9.
Re-fit the cover plate over the control board, using the five
screws and the M5 nut and washers removed at step 2.
External Wiring
It is important to strain relieve the PROFIBUS cable before it is
connected to the drive. Strain relief helps to prevent damage tthe
PROFIBUS connection or the cable being unexpectedly unplugged.
Electrical noise and electromagnetic interference can be introduced
into a microelectronics system via the cables and wires connected
to it. To avoid this, wiring which could carry noise, that is ‘dirty’
cables, should be kept away from cables that are to be kept free
from electrical noise or ‘clean’. Wiring that falls into the same group
can be run together, while wiring from different groups should bbe
kept apart, though paths may cross at right angles. All connections
to the PROFIBUS board are considered to be clean.
PROFIBUS Connectors
The PROFIBUS board contains 1 external connection, a 9 wayD.
type female connector that is used to connect to the PROFIBUS
network cable.
PCB Handling Information
An earthed anti-static wristband must be worn when handling thee
PROFIBUS board.
Receipt of Equipment on Site
Where the PROFIBUS board is shipped separate to the general
drive assembly, the equipment should be carefully unpacked and
inspected for any signs of damage. Check the complete
consignment against the packing slip for any loss in transit. If any
damage or loss has occurred, contact your local supplier
immediately giving the following details:
A list of damaged or missing items.
A description of the damage.
The order number or packing slip details.
Storage
If the equipment delivered to site is not to be installed immediately:
Re-pack it in its original packing material.
Store it in a clean dry atmosphere, preferably at room
temperature. See section 2.1.9.
Configuration Details for Drive Modules
There are two types of PROFIBUS board. The MVS3007-4001
board is identifiable by the daughter board mounted on pillars and
the presence of the 8 way Dual in Line (DiL) switch, S3.’ See Figure
3-1 MVS3007-4001 PROFIBUS Board and Figure 3-2 MVS3007
4001 PROFIBUS Layout. The MVS3007-4002 board has neithe1
the daughter board nor switch S3 fitted.
When fitted in a drive, the MVS3007-4001 and MVS3007-4002
PROFIBUS boards are differentiated by the position of the 9 pin D
connector. The connector is in the middle of the MVS3007-4001
board, whereas on the MVS3007-4002 board the connector is close
to the LED indicators.
It is important that the switches and links on the PROFIBUS bpoard
be set before installation into the drive, as changing these will
require removal of the module.
MVS3007-4001 PROFIBUS Board Configuration
The switch settings and link connections that may be configured are
shown in Tables 1 and 2. The default settings and connectionis are
recommended for MV3000e applications and are indicated by一
asterisks
Switch Settings
The MVS3007-4001 PROFIBUS board has two Dual-in-Line
switches, S2 and S3. which must be configured as per Tables3-1
and 3-2.
The switches are located as shown inside the frontcover
Table 3-1 Switch S2 meanings