SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
MODEL VM-5W2 DUAL POWER SUPPLY
INSTRUMENT RACK
umber of VM-5
monitor units Husing fix screw size Tropical
spec.
2 Max.10 units
*1 0 #4-40UNC
1 M2.6×0.45
INPUT FOR
OPERATION
(FROM REAR
PANEL)
Alarm reset(normally open)
Sequence(normally open)
Filter enable(normally open)
Contact type : Dry contact
ALARM
CONTACT
OUTPUT
Function : System OK(common to all channels)*3
Contact capacity :
load resistance : 250VAC,5A
: 30VDC,5A
Contact type : C contact•Dry contact SERIAL INTERFACE
INPUT/OUTPUT
CONNECTOR *6
D-Sub connector 9P 2pc. (IN,OUT)
Housing fix screw : #4-40UNC or M2.6×0.45
Specified when ordering.
Unless specified otherwise, preset to #4-40UNC.
Recommended connector(Socket side)
Connector Housing
XM2D-0901 XM2S-0913(#4-40UNC)
XM2S-0911(M2.6×0.45 ) [OMRON]
GM(E)-9F GM-9LD55GU(#4-40UNC)
GM-9LD55G(M2.6×0.45 ) [HONDA]
CONTACT LIFE 100.000 times or more(rated load)
PROTECTIVE
CONSTRUCTION
Plastic sealed
TEMPERATURE
RANGE
Operating temperature :
0 to 65°C(32 to 149°F REF.)*2
Relative Humicity : 20 to 95%RH(noncondensing)
MATERIAL AND
FINISH
Rack(Top plate,Bottom plate) : ZAM-ZC
Rack(Side plate) : SPCC Munsell N-1.0(equiv.)
Face plate : Aluminum Munsell N-4.0(equiv.)
OPERATION
SWITCH
DANGER bypass switch MASS max.10kg(max.22lb REF.)
OTHERS
INDICATOR Power supply 1 OK indicator : Green LED
Power supply 2 OK indicator : Green LED
MODEL VM-5W2 DUAL POWER SUPPLY
INSTRUMENT RACK
(for VM-5Z5.6.7)
VM-5 SERIES MONITOR
SPECIFICATIONS
Standard Specifications Standard Specifications
VM-5W 2- /TRP
Note) *1 Max.8 units when VM-5Z0 Power Supply Backup Module is installed.
Note) *2 Operating temperature is to 0 to 50°C(32 to 122°F REF.) when VM-5Z0 Power Supply Backup Module
is installed.
*3 The system OK alarm contacts are not functional unless the VM-5P is mounted.
*4 CE means conformity with EC directive for only the rack, but not for all the units which are installed in
the rack, nor for the whole system.
*5 Ventilation holes are drilled through the top and bottom faces of the instrument rack for natural
cooling. When mounting the instrument rack within the panel, do not close these ventilation holes. If
closed, the temperature in the rack may rise to shorten the service life of electronic parts used.
Do not place anything which interrupts ventilation within 200 mm from top and bottom faces of the
instrument rack.
Do not place the apparatus which generates heat under the instrument rack.
Be careful when installing the instrument rack in a bad-ventilated closed box (instrument panel).
It may cause shortening the life time of electronic parts because of marked rising in temperature of
the instrument rack in a bad-ventilated closed box which keeps the heat in.
Cool down inside the box with a cooling fan or the like.
Especially when installing in a small closed box, use the forced-air cooling apparatus like an
electronic air conditioner.
*6 The serial interface input/output connectors are not functional unless the VM-5P1.2 is mounted.
*7 This product cannot be used in combination with VM-5Z1. VM-5Z2. or VM-5Z3. Please be sure to
use it in combination with VM-5Z5 (VM-5Z1 successor Model), VM-5Z6 (VM-5Z2 successor Model),
and VM-5Z7 (VM-5Z3 successor Model).