SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)

MODEL VM-5H4  INSTRUMENT RACK

(for VM-5Z5.6.7)

Number of VM-5 monitor units Husing fix screw size Tropical

spec.

4 Power supply : 1 unit

Monitor : Max.8 units *1

0 #4-40UNC

1 M2.6×0.45

INPUT FOR

OPERATION

(FROM REAR

PANEL)

Filter enable (normally open)

Alarm reset (normally open)

Sequence (normally open)

Contact type : Dry contact

ALARM CONTACT

OUTPUT

Function : System OK(common to all channels)

SAMSUNG SPAI-16
ABB 1VCF752000
GE DS200TCRAG2A
GE DS200TCPDG1B
GE DS200PTBAG1
GE DS200TCEAG1
GE DS200CTBAG1
Metso ITP 201
Hirchmann BRS30-16042T2T-STCZ99HHSES
Emerson IC31224G01
Emerson IC31227G01
WATLOW DIN-A-MITE C
Emerson IC31129G05
Emerson IC31132G02
Emerson 5X00605G01
Emerson 1X00884H01
Emerson IC31219G01

Contact capacity

load resistance : 250VAC, 5A

: 30VDC, 5A

Contact type : C contact•Dry contact SERIAL

INTERFACE

INPUT/OUTPUT

CONNECTOR *6

D-Sub connector 9P 2pc. (IN,OUT)

Housing fix screw : #4-40UNC or M2.6×0.45

Specified when ordering.

Unless specified otherwise, preset to #4-40UNC.

Recommended connector(Socket side)

Connector   Housing

XM2D-0901  XM2S-0913(#4-40UNC)

XM2S-0911(M2.6×0.45 )  [OMRON]

GM(E)-9F GM-9LD55GU(#4-40UNC)

GM-9LD55G(M2.6×0.45 )  [HONDA]

CONTACT LIFE 100.000 times or more(rated load)

PROTECTIVE

CONSTRUCTION

Plastic sealed

TEMPERATURE

RANGE

Operating temperature

: 0 to 65°C(32 to 149°F REF.)

*2

Relative Humidity : 20 to 95%RH(noncondensing)

MATERIAL AND

FINISH

Rack(Top plate,Bottom plate) : ZAM-ZC

Rack(Side plate) : SPCC Munsell N-1.0(equiv.)

Face plate : Aluminum Munsell N-4.0(equiv.)

OPERATION

SWITH

DANGER bypass switch MASS max.9kg(max.20lb REF.)

OTHERS

INDICATOR Power supply OK indicator : Green LED

MODEL VM-5H4  INSTRUMENT RACK

(for VM-5Z5.6.7)

VM-5 SERIES MONITOR

SPECIFICATIONS

Standard Specifications Standard Specifications

VM-5H 4-   /TRP

Note) *1 Max.6 units when VM-5Z0 Power Supply Backup Module is installed.

Note) *2 Operating temperature is 0 to 50°C (32 to 122°F REF.) when VM-5Z0 Power Supply Backup Module

is installed.

*3 The system OK alarm contacts are not functional unless the VM-5P is mounted.

*4 CE means conformity with EC directive for only the rack, but not for all the units which are installed

in the rack, nor for the whole system.

*5 Ventilation holes are drilled through the top and bottom faces of the instrument rack for natural

cooling. When mounting the instrument rack within the panel, do not close these ventilation holes. If

closed, the temperature in the rack may rise to shorten the service life of electronic parts used.

Do not place anything which interrupts ventilation within 200 mm from top and bottom faces of the

instrument rack.

Do not place the apparatus which generates heat under the instrument rack.

Be careful when installing the instrument rack in a bad-ventilated closed box (instrument panel).

It may cause shortening the life time of electronic parts because of marked rising in temperature of

the instrument rack in a bad-ventilated closed box which keeps the heat in.

Cool down inside the box with a cooling fan or the like.

Especially when installing in a small closed box, use the forced-air cooling apparatus like an

electronic air conditioner.

*6 The serial interface input/output connectors are not functional unless the VM-5P1.2 is mounted.

*7 This product cannot be used in combination with VM-5Z1. VM-5Z2. or VM-5Z3. Please be sure to

use it in combination with VM-5Z5 (VM-5Z1 successor Model), VM-5Z6 (VM-5Z2 successor Model),

and VM-5Z7 (VM-5Z3 successor Model).