Honeywell

TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106

TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106

The optional Touchscreen and Trackball are not to be used together on the same US, so

they share the same connector (J1) on the EPDGP I/O card.  When the Trackball or

Touchscreen is selected are bulkhead connected at the transition panel (see Figure 2-7).

1. The cables from the optional touchscreen pass through the clamps in the left location

marked TOUCHSCREEN on the lower transition panel in Figure 2-5. and are to be

connected to the EPDGP I/O card in slot 2 as shown in Figure 2-6.

2. Plug the large connector into J1. marked TOUCHSCREEN or TRACKBALL in Figure

2-6.  on the EPDGP I/O card and the small connector into J4. marked POWER in

Figure 2-6.  The EPDGP I/O card may have to be partially or completely pulled out to

make these connections.  Use proper board handling precautions, including a grounded

wrist-strap, to extract the card.  Use care not to disturb or dislodge existing cables and

then firmly reseat the card.

3. Using a cable-tie (51190879-001) on each cable, fasten the cables to their strain-relief

clamps on the upper transition panel.

2.7.11 Trackball Cabling

The cable from the optional trackball is to be connected to the lower transition panel at the

left location marked Trackball in Figure 2-5.  Use a small screwdriver to tighten the screws

(2) on the connector.  In accordance with the user’s preference, place the trackball either to

the right or left side of the keyboard

If your Enhanced Micro TDC3000 System has one color monitor and no options except a

touchscreen or trackball, there is no further cabling to be done on tower #2.  Skip this

section and proceed with subsection 2.10. Installation Wrap-Up.

If you have a second Universal Station or additional options, consult the paragraphs in this

section that deal specifically with those options and cable them accordingly.

The following subsections, where applicable, may contain information on the EMC

Triconex 3704E
Triconex 3504E
Triconex 3504E
EMERSON 1X00781H01L
EMERSON PR6423 009-041+CON 041/913-030
KONSGBERG RCU500
KONSGBERG RMP400
KONSGBERG RDIOR400
Cutler Hammer 1775K PMPP1700
MOORE INDUSTRIES MDS/PRG/10-30DC/-MAO
ABB DHH805-A

Directive that affects the hardware.  When applicable, the EMC hardware information will

usually follow the hardware that is not in compliance with the directive.

2.8.1  Optional Universal Station Upgrade

Adding this kit upgrades a basic Enhanced Micro TDC3000 System.  This involves

adding a Universal Station node containing K2LCN, EPDG2. EPDGC I/O boards, and

keyboard.  The monitor is ordered separatly.  Refer to MX-MTUS34 or MX-MTUS36

Upgrade Kit Installation Instructions for directions for upgrade.

2.8.2  Optional Redundant Network Interface Module

The redundant NIM, in conjunction with a redundantly-connected Advanced Process

Manager, provides a level of protection in case of equipment failure

Ref. #

Cabling for the Universal Station is shown in the following figure and table.

Application Notes

51192126-200 Video Cable

51308099-100 Mouse/Trackball Interface Cable

Not Applicable

51308103-003 Printer Cable – 3 meters/9.8 ft.

51308103-008 Printer Cable – 8 meters/26.3 ft.

51308103-015 Printer Cable — 15 meters/49.2 ft.

51192054-101 Cable,SCSI Shielded, 50 position

51305070-200 Cable, SCSI

51308110-100 Cartridge DC Power Cable

51308109-100 Cartridge DC Power Cable (in Enclosure)

51308105-200 Keyboard Interface Cable

51308104-100 Keyboard Interface Cable (in Keyboard Tray)

51304496-046 Engineer”s Keyboard Cable (in Keyboard Tray)