Shinkawa RiverNew Vibration Transducer VK202 Series

Shinkawa RiverNew Vibration Transducer VK202 Series

The Shinkawa RiverNew VK202 Vibration Transducer System is a high-precision, non-contact eddy-current monitoring system designed for continuous vibration, axial displacement, and rotational speed measurement on critical rotating machinery. Built by Shinkawa Electric Co., Ltd., the VK202 non-contact sensing loop converts changes in distance between the probe tip and target shaft into an accurate, linear voltage output.

A standard RiverNew VK202 system consists of three modular components:

VL-202 Proximity Sensor Probe

VW Extension Cable

VK-202 Driver / Signal Conditioner

Technical Table

Parameter Specification Details
Manufacturer Shinkawa Electric Co., Ltd.
Series Name RiverNew VK-202 / VK-A Series
Transducer Type Non-contact Eddy-Current Displacement System
Measurement Range Standard linear range up to 2.0 mm (2,000 $\mu\text{m}$)
Sensitivity / Scale Factor ~7.87 mV/$\mu\text{m}$ ($200\text{ mV/mil}$) standard
System Power Supply -24 V DC nominal (-18 V DC to -26 V DC operating range)
Output Signal Analog voltage output proportional to target gap distance
Target Material Standard Steel (JIS S45C / AISI 4140) calibration base

Environmental Tolerance Conditions

Sensor Head Operating Temperature: -30°C to +177°C (-22°F to +350°F) for high-temperature turbine environments.

Driver Unit Operating Temperature: -20°C to +65°C (-4°F to +149°F).

Relative Humidity: 5% to 95% RH (non-condensing); oil and splash-resistant sensor design.

Corrosion Immunity: Stainless steel sensor body construction resistant to lube oil, fuel vapor, and chemical contaminants.

Operating Instructions

Check Gap Voltage: Mount the VL-202 probe so the baseline gap setting matches the recommended mid-range DC voltage output (typically -10 V DC to -12 V DC depending on system setup).

Ensure Signal Shielding: Run extension cables inside dedicated grounded conduits to protect sensitive signal frequencies from high-voltage motor EMI.

Avoid Target Interference: Maintain a minimum clearance distance around the target shaft area equal to twice the probe tip diameter to eliminate metal side-wall interference.

Fault Diagnosis & Troubleshooting

Symptom Probable Cause Corrective Action
Output Saturation (Full Supply Voltage) Open circuit or disconnected cable between driver and probe. Check coaxial extension cable pins and coaxial connectors for physical damage or loose connections.
Zero Voltage Output / Near Zero Probe tip touching target metal directly or grounded signal wire. Back probe away from shaft; measure gap distance and check wiring insulation.
Excessive Signal Noise / Erratic Readings Ground loop formation or electrical runout on target shaft. Verify shield wiring is grounded at one end only (at driver/rack) and inspect target shaft surface.

Related Models of the Same Series

Sensors: VL-202A, VL-202B, VL-501 Proximity Probes

Drivers: VK-202A, VK-202A1. VK-202A2. VK-202A4 Signal Drivers

Extension Cables: VW-202 Series Coaxial Cable Assemblies

Legacy & Partner Series: Shinkawa VK-A Series, VK-143P, FK-45223 Driver Systems

Storage Conditions

Storage Temperature: -40°C to +80°C (-40°F to +176°F).

Packaging: Keep all probe tips and coaxial connectors covered with protective dust caps when stored.

Cable Storage Handling: Store extension cables coiled loosely with a bend radius of no less than 50 mm to avoid damaging internal coaxial shielding.