The Shinkawa RiverNew VK202 Vibration Transducer System is a high-precision, non-contact eddy-current monitoring system designed for continuous vibration, axial displacement, and rotational speed measurement on critical rotating machinery. Built by Shinkawa Electric Co., Ltd., the VK202 non-contact sensing loop converts changes in distance between the probe tip and target shaft into an accurate, linear voltage output.
A standard RiverNew VK202 system consists of three modular components:
VL-202 Proximity Sensor Probe
VW Extension Cable
VK-202 Driver / Signal Conditioner
Technical Table
| Parameter | Specification Details |
| Manufacturer | Shinkawa Electric Co., Ltd. |
| Series Name | RiverNew VK-202 / VK-A Series |
| Transducer Type | Non-contact Eddy-Current Displacement System |
| Measurement Range | Standard linear range up to 2.0 mm (2,000 $\mu\text{m}$) |
| Sensitivity / Scale Factor | ~7.87 mV/$\mu\text{m}$ ($200\text{ mV/mil}$) standard |
| System Power Supply | -24 V DC nominal (-18 V DC to -26 V DC operating range) |
| Output Signal | Analog voltage output proportional to target gap distance |
| Target Material | Standard Steel (JIS S45C / AISI 4140) calibration base |
Environmental Tolerance Conditions
Sensor Head Operating Temperature: -30°C to +177°C (-22°F to +350°F) for high-temperature turbine environments.
Driver Unit Operating Temperature: -20°C to +65°C (-4°F to +149°F).
Relative Humidity: 5% to 95% RH (non-condensing); oil and splash-resistant sensor design.
Corrosion Immunity: Stainless steel sensor body construction resistant to lube oil, fuel vapor, and chemical contaminants.
Operating Instructions
Check Gap Voltage: Mount the VL-202 probe so the baseline gap setting matches the recommended mid-range DC voltage output (typically -10 V DC to -12 V DC depending on system setup).
Ensure Signal Shielding: Run extension cables inside dedicated grounded conduits to protect sensitive signal frequencies from high-voltage motor EMI.
Avoid Target Interference: Maintain a minimum clearance distance around the target shaft area equal to twice the probe tip diameter to eliminate metal side-wall interference.
Fault Diagnosis & Troubleshooting
| Symptom | Probable Cause | Corrective Action |
| Output Saturation (Full Supply Voltage) | Open circuit or disconnected cable between driver and probe. | Check coaxial extension cable pins and coaxial connectors for physical damage or loose connections. |
| Zero Voltage Output / Near Zero | Probe tip touching target metal directly or grounded signal wire. | Back probe away from shaft; measure gap distance and check wiring insulation. |
| Excessive Signal Noise / Erratic Readings | Ground loop formation or electrical runout on target shaft. | Verify shield wiring is grounded at one end only (at driver/rack) and inspect target shaft surface. |
Related Models of the Same Series
Sensors: VL-202A, VL-202B, VL-501 Proximity Probes
Drivers: VK-202A, VK-202A1. VK-202A2. VK-202A4 Signal Drivers
Extension Cables: VW-202 Series Coaxial Cable Assemblies
Legacy & Partner Series: Shinkawa VK-A Series, VK-143P, FK-45223 Driver Systems
Storage Conditions
Storage Temperature: -40°C to +80°C (-40°F to +176°F).
Packaging: Keep all probe tips and coaxial connectors covered with protective dust caps when stored.