VIBRO-METER

Vibro-Meter Rack VM600SYSMK2-ABE056 1U ultra-thin rack Mk2 system

Rack  Rack slot number coding : For modules (cards) installed in the rear of the ABE056 rack, an

electronic keying mechanism known as slot number coding is used

to help ensure that the module (card) is installed in the correct slot,

as defined by the configuration (that is, by the VibroSight ® or

VM600 MPSx software).

For ABE056 racks, the rack’s slot number is configurable by DIP

switch and slot number coding requires that the rack’s slot number

is set to match the slot number used by the module (card).

Slot number coding range : 0 to 12

Slot number coding defaults : Factory assigned default values as follows:

• Slot 01 = 1 (0001 binary) for an ABE056 rack configured for use by

a VM600Mk2 system such as a VM600Mk2 MPC4Mk2 + IOC4Mk2.

• Slot 01 = 3 (0011 binary) for an ABE056 rack configured for use by

a VM600 system such as a VM600 MPC4 and IOC4T.

Notes

For a VibroSight / VM600Mk2 MPC4Mk2 + IOC4Mk2 system, the

ABE056 rack DIP switch must be set to 01. as this is the default slot

number used by the VibroSight Protect configuration software for

an ABE056 rack (VM600 – 1U).

For a VM600 MPSx / VM600 MPC4 and IOC4T system, the

ABE056 rack DIP switch is typically set to 03. as this is the default slot

number used by the VM600 MPSx configuration software for the

ABE056 rack (VM600 – 1U).

AC-input power supply

Input voltage range : 90 to 264 VAC

Input frequency range : 47 to 63 Hz

Input current : 2.5 A / 115 VAC or 1.5 A / 230 VAC

Output voltages : + 5 VDC and ±12 VDC

DC-input power supply

ABB NDCU-11
GE IS220PRTDH1A
ABB 3BDH000002R1 PM802F
HARMONIC HA-800A-3C-200
A-B T9110
A-B T9451
ROLLS ROYCE 984664H
GE SR469-P5-HI-A20
EATON MA30/D/2/SI
ABB 2TLJ020070R0500
GE KYPDACGP1
GE DS3800HIOB
GE DS3800NGRD1D1C
ABB AO2040
WOODWARD 5463-787
WOODWARD 5501-429
MOOG D651-129B
ABB HMI REF542 PLUS
ABB REF615 HBFJAEAGAAC1BAA11G
ABB REF615 HBFJAEAGAAC6BAA1XE
ABB REM620E_F NBMNAANNABC1BNN1XF
ROLLS-ROYCE H1151.0102

Nominal input (line) voltage : 24 VDC

Input voltage range : 18 to 58 VDC

Input current : 3.0 A / 24 VDC

Output voltages :+ 5 VDC and ±12 VDC

Power supply check relay

Maximum switching voltage : ± 30 VRMS / ± 42.4 VAC(PEAK) or 60 VDC

Maximum switching current : 1 A

SVM600SYSMK2-ABE056     1U ultra-thin rack Mk2 system

Environmental

According to IEC 60068-2 recommendations

Temperature

•Operating : 0 to 65 °C (32 to 149 °F)

•Storage :−40 to 85 °C (−40 to 185 °F)

Humidity

•Operating : 0 to 90 %, non-condensing

•Storage : 0 to 95 %, non-condensing

Flammability class :UL 94 HB

Indoor use : Limited to indoor use only

Approvals

Conformity : European Union (EU) declaration of conformity (CE marking).

EAC marking, Eurasian Customs Union (EACU) certificate/

declaration of conformity.

Electromagnetic compatibility : IEC / EN 61000-6-2 and IEC / EN 61000-6-4.

TR CU 020/2011.

Electrical safety : IEC / EN 61010-1.

TR CU 004/2011.

Vibration : IEC 60255-21-1 (Class 2)

Environmental management :RoHS compliant

Russian federal agency for technical

regulation and metrology (Rosstandart)

:Pattern approval certificate OC.C.28.004.A N° 60224

Physical

Dimensions : See Mechanical drawings on page 5

Weight : 2.5 kg (5.5 lb) approx.

with integrated power supply (RPS1U) and modules (cards)