Rack Rack slot number coding : For modules (cards) installed in the rear of the ABE056 rack, an
electronic keying mechanism known as slot number coding is used
to help ensure that the module (card) is installed in the correct slot,
as defined by the configuration (that is, by the VibroSight ® or
VM600 MPSx software).
For ABE056 racks, the rack’s slot number is configurable by DIP
switch and slot number coding requires that the rack’s slot number
is set to match the slot number used by the module (card).
Slot number coding range : 0 to 12
Slot number coding defaults : Factory assigned default values as follows:
• Slot 01 = 1 (0001 binary) for an ABE056 rack configured for use by
a VM600Mk2 system such as a VM600Mk2 MPC4Mk2 + IOC4Mk2.
• Slot 01 = 3 (0011 binary) for an ABE056 rack configured for use by
a VM600 system such as a VM600 MPC4 and IOC4T.
Notes
For a VibroSight / VM600Mk2 MPC4Mk2 + IOC4Mk2 system, the
ABE056 rack DIP switch must be set to 01. as this is the default slot
number used by the VibroSight Protect configuration software for
an ABE056 rack (VM600 – 1U).
For a VM600 MPSx / VM600 MPC4 and IOC4T system, the
ABE056 rack DIP switch is typically set to 03. as this is the default slot
number used by the VM600 MPSx configuration software for the
ABE056 rack (VM600 – 1U).
AC-input power supply
Input voltage range : 90 to 264 VAC
Input frequency range : 47 to 63 Hz
Input current : 2.5 A / 115 VAC or 1.5 A / 230 VAC
Output voltages : + 5 VDC and ±12 VDC
DC-input power supply
| ABB | NDCU-11 |
| GE | IS220PRTDH1A |
| ABB | 3BDH000002R1 PM802F |
| HARMONIC | HA-800A-3C-200 |
| A-B | T9110 |
| A-B | T9451 |
| ROLLS ROYCE | 984664H |
| GE | SR469-P5-HI-A20 |
| EATON | MA30/D/2/SI |
| ABB | 2TLJ020070R0500 |
| GE | KYPDACGP1 |
| GE | DS3800HIOB |
| GE | DS3800NGRD1D1C |
| ABB | AO2040 |
| WOODWARD | 5463-787 |
| WOODWARD | 5501-429 |
| MOOG | D651-129B |
| ABB | HMI REF542 PLUS |
| ABB | REF615 HBFJAEAGAAC1BAA11G |
| ABB | REF615 HBFJAEAGAAC6BAA1XE |
| ABB | REM620E_F NBMNAANNABC1BNN1XF |
| ROLLS-ROYCE | H1151.0102 |
Nominal input (line) voltage : 24 VDC
Input voltage range : 18 to 58 VDC
Input current : 3.0 A / 24 VDC
Output voltages :+ 5 VDC and ±12 VDC
Power supply check relay
Maximum switching voltage : ± 30 VRMS / ± 42.4 VAC(PEAK) or 60 VDC
Maximum switching current : 1 A
SVM600SYSMK2-ABE056 1U ultra-thin rack Mk2 system
Environmental
According to IEC 60068-2 recommendations
Temperature
•Operating : 0 to 65 °C (32 to 149 °F)
•Storage :−40 to 85 °C (−40 to 185 °F)
Humidity
•Operating : 0 to 90 %, non-condensing
•Storage : 0 to 95 %, non-condensing
Flammability class :UL 94 HB
Indoor use : Limited to indoor use only
Approvals
Conformity : European Union (EU) declaration of conformity (CE marking).
EAC marking, Eurasian Customs Union (EACU) certificate/
declaration of conformity.
Electromagnetic compatibility : IEC / EN 61000-6-2 and IEC / EN 61000-6-4.
TR CU 020/2011.
Electrical safety : IEC / EN 61010-1.
TR CU 004/2011.
Vibration : IEC 60255-21-1 (Class 2)
Environmental management :RoHS compliant
Russian federal agency for technical
regulation and metrology (Rosstandart)
:Pattern approval certificate OC.C.28.004.A N° 60224
Physical
Dimensions : See Mechanical drawings on page 5
Weight : 2.5 kg (5.5 lb) approx.
with integrated power supply (RPS1U) and modules (cards)