VIBRO-METER

Vibro-Meter Rack  VM600SYSMK2-ABE04x  6U 19-inch rack Mk2 system

Rack    VM600SYSMK2-ABE04x     6U 19-inch rack Mk2 system

KEY FEATURES AND BENEFITS

• From the vibro-meter ® product line

• 19 ″ slimline rack with a standard height of 1U

• Robust metal construction

• Modular concept allows specific modules

(cards) to be added for machinery protection

or condition monitoring

• Cabinet or panel mounting

• Backplane supporting the VM600Mk2/ VM600

system’s Open collector (OC) bus, and power

supply distribution

• Integrated AC-input or DC-input power supply

• Power supply check relay

APPLICATIONS

• VM600Mk2/ VM600 machinery protection and/

or condition monitoring systems

DESCRIPTION

The VM600Mk2/ VM600 ABE056 slimline rack is used

to house hardware for the VM600Mk2/ VM600

series of machinery protection and/or condition

monitoring systems, from Meggitt’s vibro-meter ®

product line.

The VM600Mk2/ VM600 ABE056 slimline rack has a

standard height of 1U and provides mounting

space (rack slots) for one single-width VM600Mk2/

VM600 processing module (card pair) and a relay

module (card). This rack is particularly suitable for

industrial environments, where equipment must

be permanently installed in 19 ″ cabinets or

panels.

Different versions of the integrated RPS1U power

supply enable a VM600Mk2/ VM600 ABE056 slimline

rack to be powered using either an external AC or

DC mains supply. Both the power supplies support

a wide input voltage range.

The rack has an integrated backplane that

provides the electrical interconnections between

the integrated power supply (RPS1U) and the

installed VM600Mk2/ VM600 modules (cards). It

also includes a power supply check relay,

available at the rear of the rack, which indicates

DESCRIPTION (continued)

that the integrated power supply is operating

normally.

GE P7650B0C0B6E0A0A
triconex 3723X
triconex 3506X
triconex 3626X
ABB REF615 HBFEAEAGNCA1BNA11G
ABB SYN5302A 3BHB006716R0277
Vibro-meter VM600-RLC16
Vibro-meter VM600-IOC N
Vibro-meter VM600-RPS-6U
Vibro-meter VM600-CPU M
GE IS220UCSAH1A / IS220UCSAH1A
GE IS200TDBTH2A
GE IS200TDBSH6A
GE IS200WROBH1A
GE IS400WROGH1A
GE IS220PAICH1B
HIMA F8653X
HBM K-WTX110-A-AC1-TA-DIO-AO-NO/-AA
ABB SPHSS13
TRICONEX 3723X
TRICONEX 3506X
TRICONEX 3626X
GE MIB30HICE00000

VM600Mk2/ VM600 processing modules (cards) are

installed in the front of the rack and the

associated input /output modules (cards) are

installed in the rear. The input /output modules

(cards) provide connectors for the connection of

sensors/measurement chains and for the sharing

of various signals with external systems such as a

DCS or PLC.

In general, VM600Mk2/ VM600 ABE056 slimline

racks are configured in the factory before

delivery so they are supplied ready-to-use.

Optionally, each module (card) can be

reconfigured to meet the needs of a particular

machinery monitoring application using the

appropriate software package from

Meggitt Vibro-Meter : VibroSight ® or VM600 MPSx.

For further information, contact your local

Meggitt representative.

General

Housing : Zinc-plated painted sheet steel

Colour :Grey white (RAL 9002)

Power supply :An integrated RPS1U power supply provides the VM600Mk2/ VM600

rack itself and all installed modules (cards) with + 5 VDC and

±12 VDC.

See also AC-input power supply on page 3 and DC-input power

supply on page 3.

Power supply input : The power supply input has an AC or DC connector (with an

RFI filter) and an on/off switch.

See Ordering information on page 6 for information on mains power

supply leads (power cords).

Backplane :Proprietary VM600Mk2/ VM600 rack bus (Open collector (OC) bus)

for data/signal sharing between modules (cards)

Rack slots

(module (card) positions)

: Front of rack:

• 1 × slot – module (card) position 01 – for a processing module

(card) such as MPC4Mk2. XMx16. MPC4 or AMC8.

Rear of rack:

• 1 × slot – module (card) position 01 – for an associated input /

output module (card) such as IOC4Mk2. XIO16T, IOC4T or IOC8T.

• 1 × slot – module (card) position 00 – for an associated relay

module (card) such as RLC16Mk2 or RLC16.

See also Mechanical drawings on page 5.

Notes

In general, associated input /output modules (cards) are required

while relay modules (cards) are optional.

For safety reasons, any VM600Mk2/ VM600 rack slot not populated

by a module (card) must be covered by a blank panel.