OMRON CS1W-SCU31-V1 CVM1-BC103 PLC
OMRON CS1W-SCU31-V1 CVM1-BC103 PLC
LSS Operations
This section describes LSS operations required for communications with the ID
Controller and settings in the LSS’s System Setup necessary for the ID Control
ler. Perform these operations before using the LSS for the ID Controller.
Caution Be sure to set the correct PC model (ID Controller) before using the LSS. All LSS
data will be cleared if the PC model specified in the LSS System Setup is
changed from one PC group to another. (Even if the PC model is changed within
the same group, the I/O table, I/O comments, time chart data, data trace data,
and step trace data are deleted.)
PC Model for ID Controller
Expansion Instructions
Program Transfer
Set the PC model to the CQM1 when using the LSS for the ID Controller. Press
the K Key on the System Setup Menu to specify the PC model setting and then
press the E Key to specify the CQM1. (The LSS treats the ID Controller as a
CQM1 PC.)
Go to online LSS operations and transfer the expansion instructions from the ID
Controller to the LSS. Press the A Key from the online Utility Menu and then con
firm the operation on the prompt that appears next.
When transferring the program from the ID Controller to the computer running
the LSS, specify “E:SEND TO END.” This will ensure that the expansion instruc
tions table will transferred to the computer after transfer of the program has been
completed.
Note To avoid having to go online with the ID Controller to transfer the expansion
instructions each time you use the LSS for the ID Controller, you can transfer
them to the LSS once and then save them to disk using the A:RETRIEVE/SAVE
INSTRUCTIONS operation on the offline Utility Menu. Once the expansion
instructions have been saved to disk, the A:RETRIEVE/SAVE INSTRUCTIONS
operation can be used to retrieve them to use the LSS offline for the ID Control
ler

CS1W-SCU31-V1
SSS Operations
This section describes SSS operations required for communications with the ID
Controller and settings in the SSS’s System Setup necessary for the ID Control
ler. Perform these operations before using the SSS for the ID Controller.
| A06B-6114-H109 FANUC ALPHA I SERVO MODULE MDL SVM1-360I |
| 2094-BC04-M03-M Allen-BradleyKinetix 6000 Drive system module |
| MDX61B0015-5A3-4-00 SEW actuating motor |
| MDX61B0022-5A3-4-00 SEW actuating motor |
| XVH-340-57MPI-1-10 EATON Control tableau |
| 853-045677-105 LAM Rocker valve interface plate |
| 140CPU53414B CPU MODULE Schneider |
| PM2210 ABB S800 Processor |
| 2711-B5A8L1 Allen-Bradley PanelView Standard Operator terminals |
| 1794-IF8IH Allen-Bradley HART analog module |
| 330171-00-20-90-02-CN Proximity Transducer System Bently Nevada |
| REF615E_G HBFNAEAGNHALBMG11G Feeder protection and control ABB |
| 330103-00-10-10-02-00 Bently Nevada Proximity Probes |
| 2711P-RDT12H/B keypad operated terminals Allen Bradley |
| MSK040C-0450-NN-S1-UP0-NNNN Synchronous servo motors REXROTH |
| MDX61B0014-5A3-4-00 SEW actuating motor |
| MPL-B860D-MJ74AA Allen-Bradley MPL Series brushless motor |
Caution Be sure to set the correct PC model (ID Controller) before using the SSS. All SSS
data will be cleared if the PC model specified in the SSS System Setup is
changed from one PC group to another. (Even if the PC model is changed within
the same group, the I/O comment, I/O table, time chart data, data trace data, and
step trace data are deleted.)
PC Model for ID Controller
Expansion Instructions
Program Transfer
Set the PC model to the CQM1 when using the SSS for the ID Controller. Press
the K Key on the System Setup Menu to specify the PC model setting and then
press the H Key to specify the CQM1. (The SSS treats the ID Controller as a
CQM1 PC.)
The expansion instructions for the ID Controller are already registered in the
SSS. It is thus not necessary to transfer the expansion instructions when using
the SSS; just be sure to transfer the instructions table.
When transferring the program from the ID Controller to the computer running
the SSS, specify “E:SEND TO END.” This will ensure that the expansion instruc
tions table will transferred to the computer after transfer of the program has been
completed