The status of displayed bits can be changed at this point. Refer to

3-3-19 Binary Data Modification for details.

b) The Up or Down Cursor Key can be pressed to display the status

of the previous or next word’s bits.

3. Press the CLR Key to end binary monitoring and return to the normal moni

toring display.

Press the SHIFT+CLR Keys to end monitoring altogether.

3-3-18 Hexadecimal, BCD Data Modification

This operation is used to change the BCD or hexadecimal value of a word

being monitored using the procedure described in 3-3-12 Bit, Digit, Word

Monitor. It is possible in MONITOR or PROGRAM mode only.

RUN MONITOR PROGRAM

No

OK

Words SR 253 to SR 255 cannot be changed.

1. 2. 3…

OK

1. Monitor the status of the desired word according to the procedure described

in 3-3-12 Bit, Digit, Word Monitor. If two or more words are being monitored,

the desired word should be leftmost on the display.

2. Press the CHG Key to begin hexadecimal, BCD data modification.

1756-L81ES   Allen-Bradley GuardLogix controller module
1783-BMS12T4E2CGNK Allen-Bradley PoE   Ethernet switch
1408-EM3A-ENT Allen-Bradley power monitor   module
H1127.0101 Rolls-Royce Marine Controller
IS420UCSCS2A GE Mark VIe Controller
FBM224 P0926GH FOXBORO Discrete Output   Interface Module
FBM224 P0926GQ FOXBORO Discrete Output   Interface Module
1734-OB8E Allen-Bradley POINT I/O module   which features Eight (8) electronically
2711P-T7C21D8S-B Allen-Bradley Panelview   Plus 7 Operator Terminal
F650-B-F-B-F-2-G-1-HI-C-6-E GE Multilin   F650
VMIVME-7750-234 GE VME Single Board   Computer
1764-24BWA Allen-Bradley MicroLogix 1500   Programmable Logic Controller (PLC)
2711-K6C20L1 Allen-Bradley PanelView 600   Standard Operator Terminal
2711P-RP1 Allen-Bradley PanelView Plus   Operator Terminals

If a timer or counter is leftmost on the display, its PV will be displayed and will

be the value changed.

In MONITOR mode, the timer’s PV will be counting down if the timer is on.

3. Input the new PV and press the WRITE Key to change the PV. Be sure to

input timer or counter PVs in BCD only.

The operation will end and the normal monitoring display will return when

the WRITE Key is pressed.

C

2 A

0 A

0 WRITE

The timer’s PV will continue counting down from the new PV if the timer is

on.

3-3-19 Binary Data Modification

This operation is used to change the status of a word’s bits when the word is

monitored using the procedure described in 3-3-17 Binary Monitor. It is pos

sible in MONITOR or PROGRAM mode only.

RUN MONITOR PROGRAM

CVM1-CPU21-V2

Bits SR 25300 to SR 25507 cannot be changed.

1. 2. 3…

OK​

1. Monitor the status of the desired word according to the procedure described

3-3-17 Binary Monitor.

2. Press the CHG Key to begin binary data modification.

A flashing cursor will appear over bit 15. The cursor indicates which bit can

be changed.

3. Three sets of keys are used to move the cursor and change bit status:

a) Use the Up and Down Cursor Keys to move the cursor to the left and

right

Use the 1 and 0 keys to change a bit’s status to on or off. The cursor will

move one bit to the right after one of these keys is pressed.

c) Use the SHIFT+SET and SHIFT+RESET Keys to force-set or force-re

set a bit’s status. The cursor will move one bit to the right after one of

these keys is pressed. The NOT Key will clear force-set or force-reset

status.