Omron NS12-TS01B-V2 Interactive Display
Omron NS12-TS01B-V2 Interactive Display
The E5DC is an ultra-slim DIN mounted
Temperature controller that is ideal for
in-panel applications. Connections to HMI
and PLCs are seamless and do not require
programming.
• A slim body at 85 22.5 mm (D W) that fits into narrow control
panels and mounts to DIN Track.
• Removable terminal block for easy replacement to simplify maintenance.
• Select from models with screw terminal blocks and models with
Push-In Plus terminal blocks for reduced wiring work.
• No need for power supply and communication line wiring when
using connectors with Push-In Plus terminal blocks.
(Maximum connectable units: 16)
• High-speed sampling at 50 ms for applications with high-speed
temperature increases.
• Easy connections to a PLC with programless communications.
• Set up the Controller without wiring the power supply by connecting to
the computer with a Communications Conversion Cable (sold separately).
Setup is easy with the CX-Thermo (sold separately).
• Models are available with up to 2 auxiliary outputs and 1 event input
to complete basic functions.
• A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.
The control output can be used as a simple transfer output for the Digital Temperature Controllers manufactured in July 2014 or later.
*2.Option 000 can be selected only if two auxiliary outputs are selected.
*3.Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*4.Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*5.Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.
Heating and Cooling Control
Using Heating and Cooling Control
A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating
and cooling.
This allows you to handle control systems with different heating and
cooling response characteristics
E5DC-RX0ASM-015 E5DC-RX0DSM-015
E5DC-RX0AUM-015 E5DC-RX0DUM-015
2—E5DC-RX2ASM-000 E5DC-RX2DSM-000
E5DC-RX2AUM-000 E5DC-RX2DUM-000
Detection for single
phase heater
RS-485 E5DC-RX2ASM-002 E5DC-RX2DSM-002
E5DC-RX2AUM-002 E5DC-RX2DUM-002
1—E5DC-RX2ASM-017 E5DC-RX2DSM-017
E5DC-RX2AUM-017 E5DC-RX2DUM-017
Voltage output
(for driving SSR)——–
RS-485 E5DC-QX0ASM-015 E5DC-QX0DSM-015
E5DC-QX0AUM-015 E5DC-QX0DUM-015
2—E5DC-QX2ASM-000 E5DC-QX2DSM-000
E5DC-QX2AUM-000 E5DC-QX2DUM-000
Detection for single
phase heater
RS-485 E5DC-QX2ASM-002 E5DC-QX2DSM-002
E5DC-QX2AUM-002 E5DC-QX2DUM-002
1—E5DC-QX2ASM-017 E5DC-QX2DSM-017
E5DC-QX2AUM-017 E5DC-QX2DUM-017
Linear current
output——–
RS-485 E5DC-CX0ASM-015 E5DC-CX0DSM-015
E5DC-CX0AUM-015 E5DC-CX0DUM-015
2—E5DC-CX2ASM-000 E5DC-CX2DSM-000
E5DC-CX2AUM-000 E5DC-CX2DUM-000
RS-485 E5DC-CX2ASM-015 E5DC-CX2DSM-015
E5DC-CX2AUM-015 E5DC-CX2DUM-015
1—E5DC-CX2ASM-016 E5DC-CX2DSM-016
E5DC-CX2AUM-016 E5DC-CX2DUM-016