Omron NS12-TS01B-V2 Interactive Display

Omron NS12-TS01B-V2 Interactive Display

The E5DC is an ultra-slim DIN mounted

Temperature controller that is ideal for

in-panel applications. Connections to HMI

and PLCs are seamless and do not require

programming.

• A slim body at 85  22.5 mm (D W) that fits into narrow control

panels and mounts to DIN Track.

• Removable terminal block for easy replacement to simplify maintenance.

• Select from models with screw terminal blocks and models with

Push-In Plus terminal blocks for reduced wiring work.

• No need for power supply and communication line wiring when

using connectors with Push-In Plus terminal blocks.

(Maximum connectable units: 16)

• High-speed sampling at 50 ms for applications with high-speed

temperature increases.

• Easy connections to a PLC with programless communications.

• Set up the Controller without wiring the power supply by connecting to

the computer with a Communications Conversion Cable (sold separately).

Setup is easy with the CX-Thermo (sold separately).

• Models are available with up to 2 auxiliary outputs and 1 event input

to complete basic functions.

• A white PV display (height: 8.5 mm) is easy to read when setting up,

checking alarms, and making settings in a control panel.

The control output can be used as a simple transfer output for the Digital Temperature Controllers manufactured in July 2014 or later.

*2.Option 000 can be selected only if two auxiliary outputs are selected.

*3.Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.

*4.Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.

*5.Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.

Heating and Cooling Control

Using Heating and Cooling Control

A Control Output Assignment

An auxiliary output is used as the cooling control output.

B Control

If PID control is used, you can set PID control separately for heating

and cooling.

This allows you to handle control systems with different heating and

cooling response characteristics

E5DC-RX0ASM-015 E5DC-RX0DSM-015

E5DC-RX0AUM-015 E5DC-RX0DUM-015

2—E5DC-RX2ASM-000 E5DC-RX2DSM-000

E5DC-RX2AUM-000 E5DC-RX2DUM-000

Detection for single

phase heater

RS-485 E5DC-RX2ASM-002 E5DC-RX2DSM-002

E5DC-RX2AUM-002 E5DC-RX2DUM-002

1—E5DC-RX2ASM-017 E5DC-RX2DSM-017

E5DC-RX2AUM-017 E5DC-RX2DUM-017

Voltage output

(for driving SSR)——–

RS-485 E5DC-QX0ASM-015 E5DC-QX0DSM-015

E5DC-QX0AUM-015 E5DC-QX0DUM-015

2—E5DC-QX2ASM-000 E5DC-QX2DSM-000

E5DC-QX2AUM-000 E5DC-QX2DUM-000

Detection for single

phase heater

RS-485 E5DC-QX2ASM-002 E5DC-QX2DSM-002

E5DC-QX2AUM-002 E5DC-QX2DUM-002

1—E5DC-QX2ASM-017 E5DC-QX2DSM-017

E5DC-QX2AUM-017 E5DC-QX2DUM-017

Linear current

output——–

RS-485 E5DC-CX0ASM-015 E5DC-CX0DSM-015

E5DC-CX0AUM-015 E5DC-CX0DUM-015

2—E5DC-CX2ASM-000 E5DC-CX2DSM-000

E5DC-CX2AUM-000 E5DC-CX2DUM-000

RS-485 E5DC-CX2ASM-015 E5DC-CX2DSM-015

E5DC-CX2AUM-015 E5DC-CX2DUM-015

1—E5DC-CX2ASM-016 E5DC-CX2DSM-016

E5DC-CX2AUM-016 E5DC-CX2DUM-016​