KEBA KEMRO K2-400 Bus Coupler Module BL 450/A | 054202 |
Digital outputs
DO 242/B DO 272/A
Number of outputs 8 14
Nominal voltage 24 V DC
Processing time 1 ms
Nominal current of digital outputs 2 A at 50 % simultaneity
Galvanic isolation Yes
Status display Orange LED
Protection facility Short-circuit protection
Max. inductive load 1 J at max 0.2 Hz
Dimensions, weight
Height 120 mm
Width 22.5 mm front plate / 32.5 mm incl. plug
Depth 100 mm
Weight 130 g
General
Digital inputs
DM 272/A DM 276/A
Number / wiring of inputs 8x sink 6x source
Input type Type 1 (acc. to EN 61131-2)
Voltage range for “1” 15 V ≤ UH ≤ 30 V
Voltage range for “0”-3 V ≤ UL ≤ 5 V
Debouncing Configurable 1 ms, 100 ms
Cycle time 1 ms
Status display Green LED
Galvanic isolation Yes, electric strength 707 V with isolated ground connection
Interrupt inputs
Number of inputs Two of the digital inputs can be used as interrupt inputs
Voltage range for “1” 15 V ≤ UH ≤ 30 V
Voltage range for “0”-3 V ≤ UL ≤ 5 V
Response time of the K-bus interrupt 50 μs
Status display Green LED
| RELIANCE | 770.90.00CXQ |
| RELIANCE | 770.90.10 |
| RELIANCE | 803.65.00 BOARD |
| RELIANCE | DBU-400 |
| RELIANCE | DDS-LPS |
| RELIANCE | DM-20 |
| RELIANCE | DSA-MTR60D |
| RELIANCE | E243 |
| RELIANCE | MC-D5006-A |
| RELIANCE | S-D4006 |
| RELIANCE | S-D4006-F |
| RELIANCE | S-D4007 |
| RELIANCE | S-D4008 |
| RELIANCE | S-D4009-D |
Galvanic isolation Yes
DO 242/B DO 272/A
Supply voltage 24 V DC from front (nominal voltage tolerance: 19.2 V … 30 V, acc. to EN 61131-2)
24 V DC from K-bus, 5 V DC from K-bus
Overvoltage category II
Protection class III acc. to EN 61131-2
Addressing on K-bus Via 16-digit address switch, on the side
Type of terminals Open – pitch 5.08 mm
Displays on the front plate 16 signal status LEDs
Max. power consumption K-bus 24 V 2.1 W 2.1 W
Max. power consumption K-bus 5 V 0.4 W 0.4 W
Product features
• Up to 8 digital inputs
• 8 digital 2 A outputs
• 2 digital inputs with interrupt
• Short-circuit detection
• Permanently short-circuit proof
• Electronic rating plate
Short description
The DM 27x/A series is a digital input/output module of the KeConnect C2 product line and enables the connection of 6
or 8 digital inputs and 8 digital outputs. 24 V DC control signals are captured by the digital inputs and transmitted galva
nically isolated to the higher-level automation device. In addition, two of the digital inputs can be used as interrupt inputs.
The digital outputs switch the 24 V DC control signals of a CPU module galvanically isolated from the connected actua
tors. In addition to the short-circuit connection, outputs that cause short circuits can be switched off individually.
This module is attached directly to a CPU module or can be operated with all KEBA controls by means of a bus coupler