Keba Ketop T70-RQA-AK0-LK Control Panel Mobile Panel Teach Pendant Panel
Product features
• 4 analog voltage inputs usable as differential inputs
or as single-ended inputs
• Resolution 14 bit
• Sensor failure detection
• Electronic parameter chip
Short description
Analog input module KeConnect AI 240/A features four analog voltage inputs that process differential or ratiometric input
signals in the range from ±10 V or 0-10 V with a resolution of 14 bit.
A sensor failure, should it occur, is reported to the higher-level central module and can be evaluated in the application.
This module is attached directly to a CPU module or can be operated with all KEBA controls by means of a bus coupler
Digital outputs
DM 272/A DM 276/A
Number / wiring of outputs 8x source 8x sink
Nominal voltage 24 V DC
Processing time 1 ms
Nominal current of digital outputs 2 A at 50 % simultaneity
Protection facility Short-circuit protection
Max. inductive load 1 J at max 0.2 Hz
Status display Orange LED
Galvanic isolation Yes, from the control electronics and between one another,
electric strength 707 V with isolated ground connection
Dimensions, weight
Height 120 mm
Width 22.5 mm front plate / 32.5 mm incl. K-bus plug
Depth 100 mm
Weight 135 g
General
| RENATA | CR2450N |
| RENAULT CIRCUIT | CU-8593-IND.A |
| REOTRON | 567LH-DP24 |
| REXROTH | 0608 801 006 |
| REXROTH | 0608720040 |
| REXROTH | 0608800048 |
| REXROTH | 0608820069 |
| REXROTH | 0608820103 |
| REXROTH | 0608820116 |
| REXROTH | 0608830174 |
| REXROTH | 0608830222 |
| REXROTH | 4WE6Y62/EG24N9K4 R900561276 + HSZ10-26916-AA/G24N9K4M01 R901025684 |
Supply voltage 24 V DC from front
(nominal voltage tolerance: 19.2 V to 30 V, acc. to EN 61131-2)
24 V DC from K-bus, 5 V DC from K-bus
Overvoltage category II
Protection class III acc. to EN 61131-2
Addressing on K-bus Via 16-digit address switch, on the side
Type of terminals Open – pitch 5.08 mm
Max. power consumption K-bus 24 V 1.9 W
Max. power consumption K-bus 5 V 0.4 W
Analog inputs
Number / type of inputs 4 voltage inputs
Resolution 14 bit
Signal range ±10 V or 0 – Uref (10 V)
Max. measurement signal ±10.4 V
Input type Differential or single-ended
Galvanic isolation No
Reference voltage output 10 V ±2.5 %; max. 20 mA
Scan repeat cycle 1 ms
Input impedance in signal range 10 MΩ
Input filter characteristic – order First order
Input filter limiting frequency 250 Hz
Conversion method Successive approximation
Monotonicity without error codes Yes
Synchroneity control ±13.5 V
Synchroneity suppression > 80 dB
Value of the lowest bit (LSB) 1.3 mV
Maximum permitted continuous load (wit
hout damage) ±30 V
Typ. temp. coefficient measurement error ±5 ppm of scale end value / °C
Max. temp. coefficient measurement error ±20 ppm of scale end value / °C
Largest error at 25 °C ±0.01 % of scale end value