Plant personnel frequently use hand-held radios (“walkie-talkies”), or citizens-band
radios mounted in maintenance vehicles, for communications. To avoid RFI problems,
review the following:
• If radio communications must take place within an operating area or process
controller area, a base-station transceiver with an external antenna should be
used.
• For other applications, radio transmitters with outputs rated as high as 5 watts
must be kept at least 3 meters (10 ft.) from the Enhanced Micro TDC3000
equipment during operation. Transmitters with outputs higher than 5 watts
must be kept as far as possible from your equipment. Keep equipment doors
closed while operating.
Other sources of RFI include generators, arcing relays, or motor contacts, etc.
8. Follow proper cleaning procedures when cleaning the operator area or the control room:
• Do not use water freely. Mop should be only dampened, not wet or dry.
• Use a lint-free, antistatic-type dust cloth to remove dust.
• Do not sweep around areas containing cartridge disks or drives.
• Use a vacuum cleaner on carpets—preferably one connected to an external
system.
• Do not allow liquids to be placed on the Enhanced Micro TDC3000 keyboards
and equipment. Liquid spills will damage electronic components.
9. Clean the cartridge disk drive as outlined in the Universal Station Service manual in the
LCN Service – 1 binder to prevent errors and loss of data when loading programs.
10. Regularly clean the CRT face to minimize operator fatigue. Cleaning procedures are
found in Universal Station Service manual in the LCN Service – 1 binder.
11. Clean the printer before startup and periodically thereafter, as described in the
Universal Station Service manual in the LCN Service – 1 binder.
12. Periodically clean the operator and engineer keyboards by dampening a cloth with mild
detergent and wiping the keys. Do not spray detergent solution on the keys as moisture
may ruin the circuits underneath.
13. Periodically check and clean or replace the air filters in each cabinet. Refer to
subsection 6.3.1 of this manual for filter removal and cleaning procedures.
| KERN MOTOR 3Ph 2903400.001 5 x1 KERN MOTOR 3Ph 2903400.001 6 x1 |
| SIGMATEK DAI 401 |
| SIGMATEK DAI411 DIAS KTY10 05-020-411 |
| OMRON CJ2M-CPU31 |
| SIGMATEK DTO163 05-007-163 |
| SCHNEIDER LV431549 |
| EMERSON / CONTROL TECHNIQUES UD51 ISS4 2ND ENCODER OPTION MODULE STDJ19 |
| GREIN SAB/BOX A5RT |
| HMS Industrial AB7126-B ABC-PDP-EH Anybus X-gateway Interface for PROFIBUS-DP |
| REXORTH VT5005 S16 R5 11110027 |
| WEIDMULLER UR20-4AI-UI-12 1394390000 |
| TOSHIBA TRANSISTOR INVERTER VFNC1S-2004PL-W |
| B&R X20DS1928 REV.B5 |
| SIEMENS SIMATICS 6SL3224-0BE23-0AA0 |
| SCHNEIDER ELECTRIC BMXP342020 |
| SCHNEIDER ELECTRIC BMXAMI0810 |
| SETEX CPU LOGIMAT P160 |
| Tac Xenta 401:C |
| Siemens 6FX3002-5CL02-1CA0 Servo Cable |
| CROWN ACCESS-6 GUIDANCE MODULE TSP 130955 |
| JUMO TYA-110/325400TR 70/00088113 |
| SETEX DM016V3 BGC04112 |
| LENZE E82EV152_2C 13436167 5A39 |
| LENZE E82EV152_2B 00450762 45407021 |
| CROWN HD2500 153076 |
| OMRON CJ1W-DA041 |