TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
Generally, EMC Directive cabling on the LCN systems follow these rules:
• any cable exiting an enclosure is shielded
• cable shields are terminated at both ends of the cable to chassis ground
• metallic connector housings (back-shells) completely enclose the cable for contiguous
shield
• braid or braid over foil is used on coaxial cables
• foil is used as a sheild where applicable (on multi-pair cables).
1. Remove the rear center-section cover of both towers by removing four M5 flat-head
screws, exposing the EMC Directive I/O boards as shown in Figure 2-6. Note that the
I/O boards have the face plates attached to the free edge of the board. The face plates
are secured to the sheet metal module with screws. The cards seen in Figure 2-6 are a
typical example for Tower #1. Note some chassis slots are not used and have filler face
plates covering the board slot. The cables from these board face plates to the transition
panels will have been installed at the factory
Note there are two TP485 cards, in slots 1 and 9. The TP485 in slot 9 of each tower
provides the TPLCN interface. The TP485 in slot 1 in each tower provides the
connection, at J3 (see Figure 2-4), and interface for thermocouples that sense the
module’s temperature (non-EMC Directive equipment)
For EMC Directive cabling, the connections you will make in the following steps is on
the transition panel shown in Figure 2-7. Note there is one exposed transition panel
located at the bottom (see Figure 2-7). The panel has connectors and cable clamps on it
that will be used to secure cables you will install. Both towers have the same locations
for specific connector/clamp brackets but the bracket types in certain locations may
differ depending on the options installed
Note the Optional EPLCG Relay Panel in Figure 2-5 above. It can be mounted above
the transition panel, as shown, in the tower containing an optional EPLCG (see Section
2.8.5).
Figure 2-8 and Figure 2-9 shows the EMC Directive TP-485-3 I/O board face plate. The
designed cable(s) attached to this card face plate is also terminated to ground (sheet metal
module) through the attaching screw on the face plate. This I/O board provides the current
loop interface between the modules located in an Enhanced Micro TDC3000 tower
| GE | IS220YDOAS1A |
| GE | IS220YDOAS1A |
| GE | IS220PDOAH1B |
| GE | IS220YDIAS1A |
| GE | IS220PAOCH1B |
| SAMSON | TROVIS 6495-2 |
| BENDER | IRDH375-435 |
| BENDER | AGH150W-4 |
| ABB | 3BHE024855R0101 |
| ABB | 3BHB023302R0001 |
| ABB | 3BHE021951R0124 |
| EMERSON | CE3008 |
| EMERSON | CE4003S2B3 |
| EMERSON | CE3008 |
| EMERSON | CE4003S2B3 |
| EMERSON | CE5109 |
| KUKA | KSD1-16 |
| HONEYWELL | 05701-A-0301 |
| HONEYWELL | 05701-A-0302 |
| ABB | 3BHE021951R0124 |
| ABB | 3BHB023302R0001 |
| ABB | 3BHE024855R0101 |