OMRON CJ1W-MD261 Digital I/O

CJ1W-MD261

CJ I/O, 32 in, NPN/PNP 24 VDC schakelvertraging instelbaar, 32 uit, transistor NPN

, 24 VDC / 0.3 A, met 2 x 40 punts Fujitsu aansluiting

Specificaties

I/O system    CJ I/O Bus

Expansion unit type    Basic I/O Unit

Type of module    Digital I/O

Number of digital inputs    32

Digital input type    PNP/NPN

Permitted voltage at input    20.4-26.4 V

OFF/ON delay    0-32 ms

Number of digital outputs    32

Digital output type    NPN

Permitted voltage at output    10.2-26.4 V

Output current    0.3 A

Short-circuit protected outputs

I/O connection type    FCN (plug not included)

Number of I/O connectors    2

Detachable I/O terminal block

Suitable for safety functions

Number of IOV (V+) terminals    4

Number of IOG (V-) terminals    4

Number of COM terminals    4

Product Height (unpacked)    90 mm

Product Width (unpacked)    31 mm

Product Depth (unpacked)    66.5 mm

Product Weight (unpacked)    110 g​

Forced Status Hold Bit at

Startup

Power

ON

Non-retained parts

of I/O memory:

Retained

Power on Retained

IOM Hold Bit: 1

(ON)

Not retained when

power is turned ON.

Retained when

power is turned ON.

The Forced Status Hold Bit (A50013) can be turned ON to retain the forced

status of all bits that have been force-set or force-reset when the CPU Unit’s

operating mode is switched between PROGRAM mode and RUN/MONITOR

mode. When the PLC is turned on, the Forced Status Hold Bit itself will be

cleared (OFF) unless it is protected with this PLC Setup setting.

If the Forced Status Hold Bit at Startup setting is ON, the status of the Forced

Status Hold Bit will be protected when the PLC is turned on. If this setting is

ON and the Forced Status Hold BIt itself is ON, all force-set and force-reset

bits will retain their forced status when the PLC is turned on.

Note If the backup battery fails or is disconnected, the Forced Status Hold Bit will

be cleared whether this setting is ON or OFF.

OFF (0):   Forced Status Hold Bit cleared at start-up

Forced bit status

Mode switch Retained

Forced Status

Hold Bit: 1 (ON)

Forced bit status

Mode switch Retained

Power

OFF

Power

PCI-7344 NI Motion Controller Device
PCI-7324 NI Motion Controller
PCI-6733 NI Analog Output Device
PCI-6561 NI Digital Waveform Generator
PCI-6115 NI Multifunction I/O Device
810-017003-001 LAM Circuit board module
810-017002-003 PCB Indexer Interface LAM
810-017001-010 PCB Indexer Interface LAM
810-016434-001 PCB Indexer Interface LAM
810-015987-101 LAM Circuit board module
810-015987-003 PCB Indexer Interface LAM 810-008582-001
810-015987-001 PCB Indexer Interface LAM 810-007930-001
810-015932-003 PCB Indexer Interface LAM 810-002895-002
810-015932-002 Lam Research voltage input module
810-015932-001 LAM Circuit board module
810-010473-401 LAM Rocker valve interface plate
810-014025-004 LAM PLCs/Machine Control
810-014025-001 Lam Research voltage input module
810-013872-108 LAM Circuit board module

Forced bit status

Power ON Not retained

Forced Status

Hold Bit: 0 (OFF)

ON (1):   Forced Status Hold Bit protected at start-up

Power

OFF

Forced Status

Hold Bit: 1 (ON)

Startup Mode Setting

Power

ON

Forced bit status

Power ON Retained

Forced Status

Hold Bit: 1 (ON)

Not retained

when power is

turned ON.

Retained when

power is turned

ON.

This setting determines whether the startup mode will be the mode set on the

Programming Console’s mode switch or the mode set here in the PLC Setup.

Note If this setting specifies the mode set on the Programming Console’s mode

switch (0) but a Programming Console isn’t connected, the CPU Unit will auto

matically enter RUN mode at startup. (This differs from the default operation

for CS-series CPU Units.)

PRCN: Programming Console’s mode switch

Mode switch

setting

Power ON

Other: PC Setup’s Startup Mode setting

PRG: PROGRAM mode

MON: MONITOR mode

RUN: RUN mode

Power ON

RUN mode when

disconnected.

Power ON

Note If a Programming Console is not connected when the PLC Setup is set to use

the mode set on the Programming Console’s mode switch, the CPU Unit will

start in RUN mode.