ALSTOM PIB504-3BEE0088 4-channel optical fiber interface board
PIB314C Power Interface / Measurement Board
Introduction to the use of the second CAN port
Current models of the ALSPA MV3000e provide the Extended
I/O, CANopen and DeviceNet protocols from the CAN port
provided on the CDC control board.
The latest models of ALSPA MV3000e drives can support a
second CAN port, offering all the facilities provided on the CDC
CAN port.
This manual describes the installation and use of second CAN
port with the later models of drives that are able to support it.
This manual assumes that the user has access to the CANopen
and DeviceNet manuals listed below. These manuals provide a
detailed description of the CAN menu parameters and an
overview of the protocols provided, together with set up
examples.
T2013
T2017
2. Specification
The second CAN port supports the CANopen, Extended I/O and
DeviceNet protocols as described in the ALSPA MV3000e
CANopen user manual and the ALSPA MV3000e DeviceNet
user manual.
This software facility is incorporated as standard in drives fitted
with Version 9.00 or later:
CDC required: 20X4311 issue E or later
OR 20X4341 issue C or later
The following sub-sections supersede the equivalent sub
sections found in the above manuals.
Supported Baud Rates
In common with the primary CAN port on the CAN 2 capable
CDCs, the second CAN port can be configured to communicate
at the standard CANopen rates between 20 k Baud and 1M
Baud.
The Baud rate selection is from the following list:
• 20 k Baud
• 50 k Baud
• 100 k Baud
• 125 k Baud
• 250 k Baud
• 500 k Baud.
• 1M Baud
DeviceNet is limited to a subset of the above Baud rates, i.e.
• 125 k Baud
• 250 k Baud
• 500 k Baud
Opto-Isolation
ALSPA MV3000e 2nd CAN Port
In common with the primary CAN port on the CAN 2 capable
CDCs, full opto-isolation is provided. The opto-isolated CAN
transceiver is powered by an on-board DC to DC converter.
There is no requirement to provide CAN-side external power.
2.2 Connector Specification
Connectors and Connections
The CANbus connection is achieved via the CAN_HI and
CAN_LO and COMMS_GND terminals provided on Terminal
Block TB7/TB7B as detailed in Table 4-1.
The connections at TB7/TB7B are made by screw-type
terminations for each separate flexible cable.
All cables should have strain relief to prevent damage to the
CANbus connection at TB7/TB7B.