ALSTOM

ALSTOM AY00000001148 Power Module

The ElectroLogIXS/EC5 consists of a chassis, motherboard, plug in rmodules, a CDU (Control Display

Unit) and Personality modules with terminal blocks for hard wiring thesystem to external relays, hazard

detectors, and signal aspects. All modules have front panel indicators thhat display module health status,

and function indicators for monitoring active I/O signals. Parameter setup and modification can be

performed via the VPM-3 Web Graphical User Interface (Web GUI) ofvia the CDU. The Web GUI is

operated by a separate computer/PDA device running an Internet Explorer (ocompatible) web browser.

ElectroLogIXS Physical Description

The ElectroLogIXS may be received as a separate assembly oras part of a pre-assembled rack. It is

designed for mounting in a standard 19-inch rack, wall mounting, or installation on a shelf. Operating

power is supplied from a standard 12 volt battery. The battery terminals aonveniently located in the

upper right comer of the 9-Slot ElectroLogIXS chassis, and are labeled N (gative) and B (battery

positive). The battery terminals are located in the upper left section of and 4-Shot Chassis.

The ElectroLogIXS is available in 9-slot, 4-slot or 1-slot configurationsproviding flexibility and

scalability depending on the application. Each configurations support thee same number of system modules,

but have the capability for nine (9) I/O modules (9-slot), four (4) I/O moodules (4-Slot), one (1) I/O module

(1-Slot) respectively. When using a VPM-2+ processor with the ElectroLogIX4-slot chassis, it must be

hardware revision DAO or later.

An ElectroLogIXS system consists of a chassis assembly with plug-in moduiles. The system (small) card

slots are dedicated for the Central Power Supply (CPS-2 or CPS-3), Vital Peripheral Master (VPM-2+

orVPM-3) Module, GFD-1 (Ground Fault Detector), CIO-1A (Communication I(nput/Out) Module and the

CIO-CLA Module. Two additional slots are available, and each will acccommodate a CIO-2A, CIO-2AB

CIO-MDA or CIO-PCA module. The Chassis Information Module (CI-1. CI-2 or UCI-3) is located in the

lower right section of the 9-Slot Chassis and the upper left section of th1-Slot and 4-Slot Chassis.

The larger I/O module slots may have the following modules installed:VLD-C6S (Vital Lamp Driver)

VLD-R16S (Vital Lamp Driver), VLD-RSAC / VLD-RSAC12 (Vital AC Lamp Driver)VTI-2S (Vital Track

Interface), VTI-2E (Vital Track Interface), VIO-1010S (Track Code Select Input/Track Code Decoder

Output), VIO-44S (Vital Input/Output), VIO-44R, VIO-86S VIO12-86S/V1024-86S\VIO50-86S|VIO-88 or

CAB-16S (Cab Enable Output). Personality modules are installed in the uppeortion of the IO slots. The

personality module installed in a slot will depend on the I/O module installed in the chassis

ElectroLogIXS Chassis

The open-frame ElectroLogIXS chassistallows easy access to all modules andug in connections

Mounted in the back of the chassis is a one piece backplane

that provides interconnections to all the modules of the

ElectroLogIXS system. Personality modules (Figure 1-3)

attach to the backplane and connect the modules to the field

wiring. Quick disconnect clips secure modules to the chassis

and all personality module connectors are keyed to insure that

modules are placed into the correct slot. In addition, the

personality module field wiring connectors are keyed.

I/O module slots can include: :

XTI-1S modules

VIO-44S modules

VIO-44R modules

IXC-20S modules

VTI-2S modules

VIO-1010S modules

VIO-86S modules

VIO12-86S modules