Alstom L54E2900WG00 Printed Circuit Board
CDU Menu Structure
Home Menu – Date Time, shows active Alarms
Application Info – V-NV App CRC, Checksum, ACE info,etc
Application Selection – Select Application
Software Activation – Activate an Executive or a PTC Mapping file
EIXS Chassis/CI Mismatch – Displayed if default vital application isrunning due to
Application Integrity Data mismatch
Tracks – Set Track Protocol (VTI-2E). Track Length (VB, EC6), Tx Voltage and Rx
thresholds, Calibrate Source Resistance, View Codes, Test Mode, Code 5 Alt/Non-Alt
Cab Signaling – Status of Cab Outputs
Lamps – Lamp State, Lamp Filament Status, Lamp Test Mode
Vital Timers – View/change Vital Timers
| TRICON | 3721 |
| RELIANCE | FSBP-2 S-D4012 |
| GE | XDP-221-1-S |
| ASTEX | 0920-00013 FI20620-1 |
| woodward | 8440-2178 |
| GEA | 0011-6012-680 |
| GE | IS215VPROH1B |
| RELIANCE | FSBP-2 S-D4012 |
| GE | IS200VTURH2BAC |
| GE | IS200VCRCH1B |
| EMERSON | SLS1508 |
| ics | TC-301-0X |
| Emerson | P154 7281540 |
| lilaas | R02SCR-D0L3-00 |
| Honeywell | TN3801 |
| GE | IC695CPE330 |
Vital Inputs – View Vital Inputs status
Code Select Inputs – View Code Select Input statuses
Vital Outputs – View Vital Outputs status
Track Decoder Outputs – View Decoder Output statuses
Vital Config – View/Edit Vital Config Switches
Vital Comm – View Vital Comm I/O Statuses, Statistics, RemoteCoInfig
Office Comm – View Controls, Indications and Codeline Sttatus
LocalControl Panel – View LCP Health, Controls and Indiccations
Non-VitalI/O-ViewNon-VitalIIOstatus
Battery Alarm – View/Set battery Hi/Lo alarm levels (VTI)
Ground Fault – Set Ground Fault threshold, Low/Hi Battery Levels(GFD)
Local User Confirm-Reset LUC Timer
System Config – Alarms, Log Management (Error), Date/Time Setup,
IHRD Config -View/Edit IHRD Settings
IHRD Config -View/Edit IHRD Settings
Diagnostic Port, Vital Remote Setup, EPROM Info (loaded file), ExecInfo,
Ethernet Setup, Office Setup, LCP Setup, SNMP Enable/Disable
Personality Module LEDs Indicate Fuse Statuses
Fuses: Chassis F3: 25 Amp Battery Blade Fuse
Chassis F2: 3 Amp GFD Blade Fuse Chassis F1: 15 Amp CPS-3 Blade FusSe
VIO86S PM: 4A mini-blade VIOXX-86S/VIO-88 PM: 5A mirni-blade
VTI-2S PM: 15A mini-blade
VLD-C6S PM: 20A mini-blade
VLD-R16S PM: 30A, 30A, 3A mini-blade
CAB-16S, VIO 1010S, VIO44S PM:3A mini-blade
TIP:9A, 10A Blade