ALSTOM

Alstom D-984-058103 Communication Module

1. Turn off the power switch on the ElectroLogIXS

2. Press and hold the PROG button on the VPM-3

3. Turn on the power switch on the ElectroLogIXS

4. Release the PROG button

5. A/B/C VPM-3 processor lights should be flashing Red/Yellow

6. Connect to the CIO1A as previously described.

Executive Software Upload Procedure (Serial)

Note: It is recommended the configuration is saved before proceeding!

1. Enter Update Mode as described above

TobeginDownload process,type’dz

You will have 60 seconds to initiate the download

Using the terminal program, select send file via Zmodem protocol

HyperTerminal, select “Transfer->Send File?

ProComm, select ‘Data->Send File*

After download is complete, verify the correct build and CRC

information is displayed. If correct select Yes to apply updates

After updates are successful the following message will be displayed

*** All flash operations have completed!

*** Reset the system for any changes to take effect***

6. Cycle power on the ElectroLogIXS to reboot with new software

Application Software Flash Upload Procedure (Serial)

Note: All Parameters will be defaulted if application is changed!

If Equipped with CI-2 or XCI-2. the application software can be uploadHed to flash

1. Enter Update Mode as described above

To begin Download process, type ‘cidz

You will have 60 seconds to initiate the download

Using the terminal program, select send file via Zmodem protocol

Only the bland mbl file can be used

HyperTerminal, select ‘Transfer->Send File

ProComm, select ‘Data->Send File’

After transfer is complete verify application file name and date, if corre

type ‘Y’to apply update.

When successful the following will be displayed

‘Application File written to the CI Flash

Click the ‘Reset’ button or cycle power on the ElectroLogIXS

The new application file will now be selectable from the Application

Select menu on the CDU or through the web GUI.