GE ALSTOM ICP232 (029.359325) GEM80 CPU Controller
CPU A and CPU B
CPU A and CPUB are responsible for the system’s vital application logic jprocessing, communication and
control of the installed ElectroLogIXS/EC5 I/O modules, and thecontinual performance of the system
safety checks.
User supplied configuration information are used by CPU A and CPUB during plication program
execution and are vitally stored in non-volatile memory on the ElectroLogIXS/EC5 backplane with
Executive version 083024-726 (Crossing), 083025-637 (Interlocking), 083026(Combined) or earlier
and on UCI-3. XCI-2. CI-2 module with Executive version 083024-727 (Crossing), 083025-639
(Interlocking), 083026-829 (Combined) or newer. All modules, with the exception of the CI and
backplane modules may be replaced without loss of the system cornfiguration information.
CPU C
CPU C is the processor responsible for the non-vital application logic proessing and is the processor primarily
responsible for the ElectroLogIXS/EC5 system diagnostics and user interfaaces. CPU C provides the
communication control interface for the CDU-1. CI, CI, and CIO Modules aleong with the two Ethernet interfaces.
CPU C also maintains system-wide, non-volatile diagnostic logging in tthe Error, Recorder, Communication, and
Configuration logs. The non-vital configuration settings, such as baud ratsettings, etc. are maintained by
CPU C and are stored in non-volatile memory on the ElectroLogIXS/EC5backplane with Executive version
083024-726 (Crossing), 083025-637 (Interlocking), 083026-828 (Combined) orearlier and on UCI-3. XCI-2. CI-2. CI
module with Executive version 083024-727 (Crossing), 083025-639 (Innterlocking), 083026-829 (Combined) or
newer.
I/O Module Interface
The VPM-3 contains an interface by which the CPU A and CPU B communicate with all of the I/O
modules. The VPM-3 directs and controls communication to and from each of the I/O modules in the
ElectroLogIXS/EC5.
Cl or UCI-3 Interface
The CI Interface is the means by which the VPM-3 retrieves the vital and n-vital application programs
from the CI or UCI-3 module. For executive version 083024-727 (Crosssing), 083025-639 (Interlocking),
083026-829 (Combined) or newer the CI Interface is the means by whicthe VPM-3 retrieves all site
specific configuration – the vital and non-vital application, vital and noiguration and all PTC
files from the CI or UCI-3 module.
CDU Interface
The CDU connector on the front of the VPM-3 provides the communication path between the CPU C and
the CDU-1 or CDU-2.
CIO Interface
ElectroLogIXS/EC5
The CIO Interface is used for communication between CPU C and theCIO Modules (CIO-1/CIO-1A,CIO
CLA, CIO-2/CIO-2A, CIO-2AB, CIO-3. CIO-MD/CIO-MDA, CIO-FPCA) that are present in the system
The CIO Interface shown on the VPM provides a generic connection tothe CIO Modules, where the
specific CIO Module converts the signals into a specific electrical interfas RS-232. RS-485.and
RS-422 and current loop.