GE ALSTOM ICP232 (029.359325) GEM80 CPU Controller

CPU A and CPU B

CPU A and CPUB are responsible for the system’s vital application logic jprocessing, communication and

control of the installed ElectroLogIXS/EC5 I/O modules, and thecontinual performance of the system

safety checks.

User supplied configuration information are used by CPU A and CPUB during plication program

execution and are vitally stored in non-volatile memory on the ElectroLogIXS/EC5 backplane with

Executive version 083024-726 (Crossing), 083025-637 (Interlocking), 083026(Combined) or earlier

and on UCI-3. XCI-2. CI-2 module with Executive version 083024-727 (Crossing), 083025-639

(Interlocking), 083026-829 (Combined) or newer. All modules, with the exception of the CI and

backplane modules may be replaced without loss of the system cornfiguration information.

CPU C

CPU C is the processor responsible for the non-vital application logic proessing and is the processor primarily

responsible for the ElectroLogIXS/EC5 system diagnostics and user interfaaces. CPU C provides the

communication control interface for the CDU-1. CI, CI, and CIO Modules aleong with the two Ethernet interfaces.

CPU C also maintains system-wide, non-volatile diagnostic logging in tthe Error, Recorder, Communication, and

Configuration logs. The non-vital configuration settings, such as baud ratsettings, etc. are maintained by

CPU C and are stored in non-volatile memory on the ElectroLogIXS/EC5backplane with Executive version

083024-726 (Crossing), 083025-637 (Interlocking), 083026-828 (Combined) orearlier and on UCI-3. XCI-2. CI-2. CI

module with Executive version 083024-727 (Crossing), 083025-639 (Innterlocking), 083026-829 (Combined) or

newer.

I/O Module Interface

The VPM-3 contains an interface by which the CPU A and CPU B communicate with all of the I/O

modules. The VPM-3 directs and controls communication to and from each of the I/O modules in the

ElectroLogIXS/EC5.

Cl or UCI-3 Interface

The CI Interface is the means by which the VPM-3 retrieves the vital and n-vital application programs

from the CI or UCI-3 module. For executive version 083024-727 (Crosssing), 083025-639 (Interlocking),

083026-829 (Combined) or newer the CI Interface is the means by whicthe VPM-3 retrieves all site

specific configuration – the vital and non-vital application, vital and noiguration and all PTC

files from the CI or UCI-3 module.

CDU Interface

The CDU connector on the front of the VPM-3 provides the communication path between the CPU C and

the CDU-1 or CDU-2.

CIO Interface

ElectroLogIXS/EC5

The CIO Interface is used for communication between CPU C and theCIO Modules (CIO-1/CIO-1A,CIO

CLA, CIO-2/CIO-2A, CIO-2AB, CIO-3. CIO-MD/CIO-MDA, CIO-FPCA) that are present in the system

The CIO Interface shown on the VPM provides a generic connection tothe CIO Modules, where the

specific CIO Module converts the signals into a specific electrical interfas RS-232. RS-485.and

RS-422 and current loop.