GE

GE ALSTOM TSS-I Track Surge Suppressor

ElectroLoglXS/EC5 General Description

The ElectroLogIXS/EC5 product family is compatible with EC4 (ElectroCode 4), and Electro Code 4-

Plus train control systems. The ElectroLogIXS/EC5 is modular in design andbe configured to support

a wide range of applications. Capabilities of the ElectroLogIXS/EC5 includd fault detection, train

detection, broken rail detection, light out protection, approach liighting control, AC (Alternating

Current)power off detection, cab signal output control, vital two-wire inpck switch controller

protection, and HR relay drives for release of electric locked switches.

ElectroLogIXS/EC5 at each end of a control block send receive signaIs through the tracks. Track

circuits are used to inject and extract signals on and off the tracks. EleCode protocol composed of

coded pulses are used as the signal between the ends of the track block inLegacy track circuits. EC6

Protocol composed of EC6 messages are used as the signal between the ends of the track block in EC6 track

circuits. Using the tracks as conductors, makes it possible to detect trai(tracks shunted), provide broken

rail protection, and eliminate the need for external line wires. The codedpulses/EC6 messages are used to

establish a hand shaking protocolbetween ElectroLogIXS/EC5 and allowsynchronization between

ElectroLogIXS/EC5 systems to alternately send and receive data in bothdirections. Both hardware

protection and software detection schemes are employed to ensure fail-saffe communications and system

signaling. When using Electro Code protocol, adjacent blocks transpose the polarity of the track wires to

prevent signal detection in case of failed insulated joints. This isnot required with EC6 protocol if the

optional HMAC feature is used. The HMAC feature leverages a unique identifer between each end of the

block to provide additional protection against failed insulated joints

The ElectroLogIXS/EC5 determines train presence by detecting the absence otrack codes (tracksshunted)

and maintains space between trains so that adequate stopping distance is ensured and conflictingtraffic

routes are positively avoided. ElectroLogIXS/EC5 uses the amplitude of the transmit current measured to

determine the location of the train within a block.

Train control is achieved primarily through sequential control arnd illumination of track-side aspects

Positive train control can be achieved by adding cab signal capability to he system, or a messaging

interface that complies with the Interoperable Train Control (ITC) Wayside Interface Unit (WIU)

Requirements. Inputs to the ElectroLogIXS/EC5 include signals from tracck circuits, inputs from relay

contacts or other solid-state devices with digital outputs. The inpwhenthe read in a fail-safe manner, and are

processed by multiple microprocessors in a vital manner to provide fail-safe control outputs. The outputs

consist of track circuit signals, lamp driver signals, cab signal enables,C device drive voltages.

Ethernet ports and serial I/O ports allow the ElectroLogIXS/EC5 to communiwith other Positive

Train Control ITC compliant nodes, ElectroLogIXS, EC5. or VHLC systeems

The ElectroLogIXS/EC5 has a built in recorder that logs time-stamped vitalprovital events as well

as state changes and failures. All recorded events are user printable bothrack-side and in the office. A

set of resident diagnostic programs provide the tools necessary to performsystem trouble analysis and

repair. The ElectroLogIXS/EC5 has provisions for expansion to add radio siling capabilities, and to

operate remotely via a serial data port and either of two Ethernet ports.

RELIANCE 57C430
RELIANCE 57C443
RELIANCE 57C652
RELIANCE 6MDBN-012102
RELIANCE 770.90.00CXQ
RELIANCE 770.90.10
RELIANCE 803.65.00 BOARD
RELIANCE DBU-400
RELIANCE DDS-LPS
RELIANCE DM-20
RELIANCE DSA-MTR60D
RELIANCE E243
RELIANCE MC-D5006-A
RELIANCE S-D4006
RELIANCE S-D4006-F

发表回复