Foxboro CP40 Control Processors Brand
Pressure Seals
Pressure seals are used with the I/ASeries
Transmitters when it is necessary to keep the
transmitter isolated from the process. A sealed
system is used for a process fluid that may be
corrosive, viscous, subject to temperature extremes,
toxic, sanitary, or tend to collect and solidify.
Table2 and Table3 lists the various pressure seals
that can be used with these transmitters. To order a
transmitter with seals, both a Transmitter Model
Number and Seal Model Number are required. See
PSS2A-1Z11A for a complete listing of pressure
seal models and specifications. Also see Figure4 for
typical transmitter/pressure seal configurations.
Table 2. Pressure Seals Used with I/A Series Pressure Transmitters
Direct Connect Pressure Seal Assemblies
Seal Model Seal Description Process Connections
PSFLT Flanged, Direct Connect (Flanged Level), Flush or
Extended Diaphragm
ANSI Class 150/300/600 flanges and
BS/DINPN10/40. 10/16. 25/40 flanges
PSFAD Flanged, Direct Connect, Recessed Diaphragm ANSI CLass 150. 300. 600. 1500 flanges
PSTAD Threaded, Direct Connect, Recessed Diaphragm 1/4. 1/2. 3/4. 1. or 1 1/2 NPT internal thread
PSISD In-Line Saddle Weld, Direct Connect, Recessed
Diaphragm
| RELIANCE | 0-57C406-E |
| RELIANCE | 0-57C407-4H |
| RELIANCE | 0-57C408-B |
| RELIANCE | 0-57C411-2 |
| RELIANCE | 0-60002-6 |
| RELIANCE | 0-60007-2 |
| RELIANCE | 0-60010-E |
| RELIANCE | 0-60031-5 |
| RELIANCE | 0-60063-1 |
| RELIANCE | 0-60063-2 |
| RELIANCE | 0-60067-1 |
| RELIANCE | 0-60067-A |
| RELIANCE | 30V4060 |
| RELIANCE | 45C992 |
| RELIANCE | 57045 |
| RELIANCE | 57401 |
Lower housing of seal is in-line saddle welded to
nominal 3- or 4-inch (and larger) Pipe
PSSCT Sanitary, Direct Connect (Level Seal), Flush
Diaphragm
Process Connection to Sanitary Piping with 2-or
3-inch Tri-Clamp
PSSST Sanitary, Direct Connect (Level Seal), Extended
Diaphragm
Process Connection to 2-in Mini Spud or 4-in
Standard Spud; Tri-Clamp
Remote Mount, Capillary-Connected Pressure Seal Assemblies
Seal Model Seal Description Process Connections
PSFPS Flanged, Remote Mount, Flush Diaphragm ANSI Class 150/300/600 flanges and
BS/DIN PN10/40 flanges
PSFES Flanged, Remote Mount, Extended Diaphragm ANSI Class 150/300/600 flanges and
BS/DIN PN 10/40. 10/16. 25/40 flanges
PSFAR Flanged, Remote Mount, Recessed Diaphragm ANSI Class 150/300/600/1500 flanges
PSTAR Threaded, Remote Mount, Recessed Diaphragm 1/4. 1/2. 3/4. 1. or 1 1/2 NPT internal thread
PSISR In-Line Saddle Weld, Remote Mount, Recessed
Diaphragm
Lower housing of seal is in-line saddle welded to
nominal 3- or 4-inch (and larger) Pipe
PSSCR Sanitary, Remote Mount, Flush Diaphragm Process Connection secured with a Tri-Clamp to a
2- or 3-inch pipe
PSSSR Sanitary, Remote Mount, Extended Diaphragm Process Connection to 2-in Mini Spud or
4-inStandard Spud; Tri-Clamp
PSFFR Flanged, Remote Mount, Flush Diaphragm ANSI Class 150/300/600 flanges and DIN/BS PN
10/40