FOXBORO

Foxboro P0800DA Cable with Terminal

Adjustable Damping

Transmitter response time is normally 0.75 s, or the

electronically adjustable setting of 0 (none), 2. 4. or

8 seconds, whichever is greater, for a 90% recovery

from an 80% input step as defined in ANSI/ISA

S51.1. (For 63.2% recovery, 0.50 s with sensors B to

F, and 0.60 s for sensor A.)

Switching and Indirect Lightning Transients

Transmitter withstands transient surges to 2000 V

common mode or 1000 V normal mode without

permanent damage. Output shift is less than 1.0%.

(Per ANSI/IEEE C62.41-1980 and IEC Std. 61000-4-5.)

European Union Directives

 Complies with Electromagnetic Compatibility

Requirements of European EMC Directive

2004/108/EC by conforming to the following EN

and IEC Standards: EN 61326-1. and

IEC 61000-4-2 through 61000-4-6.

 Complies with NAMUR NE 21 Interference

Immunity Requirement, and NAMUR NE 43

overrange and underrange annunciations.

 Conforms to Applicable European Union

Directives (“CE” Logo marked on product).

RFI Effect

Output error is less than 0.1% of calibrated span for

frequencies from 27 to 1000 MHz and field intensity

of 30 V/m when transmitter is properly installed,

shielded cable in conduit, grounding, and housing

covers in place. (Per IEC Std. 61000-4-3.)

Electronics Module

Printed wiring assemblies are conformally coated for

moisture and dust protection.

Minimum Allowable Absolute Pressure vs.

Transmitter Temperature

WITH SILICONE FILL FLUID

Full vacuum: up to 121°C (250°F)

WITH INERT FILL FLUID (see Figure 1)

Figure 1. Minimum Allowable

Absolute Pressure vs. Transmitter Temperature,

Inert FC-43. 2.6 cSt at 25°C (77°F)

TEMPERATURE, ˚C-30

ABSOLUTE PRESSURE, mmHg

PHOENIX ST-SI-UK4
PHOENIX UK3N
PHOENIX UK4-T
PHOENIX UK6N
PHOENIX UMK-SE11.25-1
PHOENIX UT 4-HE SI
PHOENIX UT 4-MTD
PHOENIX UT 6-HE SI
PHOENIX CONTACT QUINT-DIODE/40 2938963
PHOENIX CONTACT QUINT-PS-100-240AC/24DC/10
PHOENIX CONTACT QUINT-PS-100-240AC/24DC/40 2938879
PHOTONETICS 3646 HE 1540
PI C-663.10
PI C-663.12
PILLAR CB6687-2L

0-25 50 100 150 200 250

TEMPERATURE, ˚F

Ease of Installation

Rotatable Topworks

allows transmitter installation in

tight places, allows indicator to be positioned in

preferred direction, and eases field retrofit.

Two Conduit Entrances

offer a choice of entry

positions for ease of installation and self-draining of

condensation regardless of mounting position and

topworks rotation.

Wiring Guides and Terminations

provide ease of

wire entry and support, plenty of space to work and

store excess wire, and large, rugged screw terminals

for easy wire termination.

Environmental Protection

The enclosure has the dusttight and weatherproof

rating of IP66 as defined by IEC 60529. and

provides the environmental and corrosion resistant

protection rating of NEMA 4X