SHINKAWA VM-772B DEVICE CONFIG
VM-772B DEVICE CONFIG
SYSTEM REQUIREMENTS
HARDWARE REQUIREMENTS
PC/AT compatible personal computer
Processor Intel Pentium® compatible (1GHz or higher)
processor clock speed recommended
Memory 4GB or higher recommended
Display 1024 X 768 or higher-resolution is recommended
Hard disk drive 1GB of available hard-disk space
Drive DVD-ROM drive
Network USB 2.0 / 1.1
Ethernet 100 BASE-TX
SOFTWARE REQUIREMENTS
Category Model Edition Version
OS Microsoft® Windows® 10 (32/64bit) Pro Any
Microsoft® Windows® 10 (64bit) Enterprise 2021LTSC
Microsoft® Windows® 10 IoT (64bit) Enterprise 2021LTSC
Microsoft® Windows® 11 (64bit) Pro Any
Microsoft® Windows Server® 2022 (64bit) Standard Any
Others Microsoft® Windows® installer - 3.1 or later
Microsoft® .NET Framework - 3.5
FTDI Virtual COM Port Driver (for
USB) - Any
CONNECTION
Supported devices : VM-7B Monitor, VM-7 Monitor*2,
DAQpod DP-2000 infiSYS Data Acquisition Unit
DAQpod AP-2000 infiSYS Data Acquisition Unit
Total input : 1 device*3
*2 Modules with firmware versions V0.9.0 or later are required.
*3 The number of devices connected at the same time is limited to 1. Connected device can
be changed by altering the IP address, if the connection is made via Ethernet.
COMMUNICATION (Ethernet)
Network : Ethernet 100Base-TX
Protocol : TCP/IP
※ Using Ethernet connection, the software cannot connect to devices while VM-771B MCL
View is connected.
COMMUNICATION (USB)
Network : USB 2.0 / 1.1
Protocol : Serial communications
DEVICE CONFIGURATION MANAGEMENT (VM-7B Monitor)
Configuration change : Monitor Type, Channel Type
Paramter change : Parameter setting of Phaser Marker,
Channel (Measurement, Alarm, Analysis),
Relay, Communication, etc.
Adjustment : GAP, Measure, Zero Shift, etc.
Others : Simulated value setting (for demo-mode),
Acquisition of login history, Time setting,
Modbus communication setting
(address assignment, scaling)
DEVICE CONFIGURATION MANAGEMENT (VM-7 Monitor)
Configuration change : Monitor Type, Channel Type
Paramter change : Parameter setting of Phaser Marker,
Channel (Measurement, Alarm),
Relay, Communication, etc.
Adjustment : GAP, Measure, Zero Shift, etc.
Others : Simulated Value Setting (for demo-mode),
Acquisition of login history, Time setting,
Modbus communication setting
(address assignment, scaling)
DEVICE CONFIGURATION MANAGEMENT (DAQpod DP-2000)
Configuration change : Monitor Type, Channel Type
Paramter change : Parameter setting of Phaser Marker,
Channel (Measurement, Analysis),
Communication, etc.
Adjustment : GAP for phase marker board,
Voltage input for analysis board, etc.
Others : Time setting
DEVICE CONFIGURATION MANAGEMENT (DAQpod AP-2000)
Configuration change : Monitor Type, Channel Type
Paramter change : Parameter setting of Phaser Marker,
Channel (Measurement, Analysis),
Communication, etc.
Adjustment : GAP for phase marker board,
Voltage input for analysis board, etc.
Others : Time setting
OTHER FUNCTIONS
Device info. display : GAP (bias) voltage, measured value,
analysis data (ampitude, phase, etc),
time, etc.
Password protection : Password authentication on start-up and
mode change to “Device Setup”.
Offline configuration : Createsfiles without connecting to a device.
SOFTWARE DISTRIBUTION MEDIA
Media : DVD-ROM
OTHERS
The XML files saved on VM-772B Device Config are used for device
registration on VM-773B infiSYS Analysis View.
※ The specifications and other items indicated herein are subject to change without notice.
※ All company and product names in this brochure are trademarks or registered trademarks