SYSTEM REQUIREMENTS

HARDWARE REQUIREMENTS

PC/AT compatible personal computer

Processor Intel Pentium® compatible (1GHz or higher)

processor clock speed recommended

Memory 4GB or higher recommended

Display 1024 X 768 or higher-resolution

Hard disk drive 15GB of available hard-disk space

Drive DVD-ROM drive

Network Ethernet 100 BASE-TX

SOFTWARE REQUIREMENTS

Category Model Edition Version

OS Microsoft® Windows® 10 (32/64bit) Pro or higher  Any

Microsoft® Windows® 11 (64bit) Pro or higher  Any

Others Microsoft® Windows® installer – 3.1 or later

Microsoft® .NET Framework  – 3.5

CONNECTION

Supported devices : VM-7B Monitor, VM-7 Monitor*2

Total input : 4 devices (Max.)*3

*2 Modules with firmware versions V0.9.0 or later are required.

*3 Multiple concurrent communication requires a hub.

COMMUNICATION

Network : Ethernet 100Base-TX

Protocol : TCP/IP

RECORDING

SHORT TERM DATA

Data : Measured values of each modules

Acquisition interval : 1 sec.

Period : 1 week

LONG TERM DATA

Data : Maximum values and mean values of

measured values

Acquisition interval : 1 hour

Period : 3 years

SCREEN

Bar graph screen : Measured values are displayed in rectangular bars.

Relay status screen : Relay status and logic is displayed.

Trend graph screen : Short term data or long term data is displayed.

Range of short term data display

: 1 hour / 30 minutes / 15 minutes / 10 minutes /

5 minutes / 2 minutes

Range of long term data display

: 3 months / 1 month / 2 weeks / 1 week /

3 days / 1 day

Train screen : Displays measured values and the train diagram.

Detailed information window

: Monitor range and alarm set values are displayed.

DISPLAY DATA

MEASURED VALUES

GAP (bias) voltage indications, Digital indication of measured values

ALARM

DANGER alarm, ALERT alarm, OK alarm (NOT-OK), GAP alarm*4.

System OK alarm (SYSTEM-OK), Power OK alarm (POWER-OK)

*4 Outputs as ALERT alarm.

STATUS

DANGER bypass status, Channel bypass status,

Demo-mode (simulated value setting mode) status, Sequence mode status,

10-pole high-pass filter (10-pole low-cut filter) status, Peak hold status,

First-out status*5. Internal bus communication abnormality status*6.

Communication board install status*7

*5 Only the ALERT LED of the module first set off DANGER/ALERT alarm flashing.

*6 Only the ALERT LED on the left-end of the screen flashing.

*7 Only available of VM-7B Monitor.

SET VALUES

Channel name, Tag name, Serial number, Firmware ID*8. Monitor range,

DANGER alarm set values, ALERT alarm set values

*8 Only available of VM-7B Monitor.

CONTROL FUNCTIONS

RESET INSTRUCTION

Alarm reset, Peak hold reset, First-out reset

BYPASS INSTRUCTION

DANGER bypass, Channel bypass

OTHER FUNCTIONS

Password protection : Password authentication is executed to

the instruction of the control operation.

Screen capture

: Captures active screen in PNG form.

CSV output

: The data of the trend graph under the display is

output by Comma Separated Value.

SOFTWARE DISTRIBUTION MEDIA

Media

!

: DVD-ROM

WARNING

Some functions may not be available with old version.

For details, please refer to “infiSYS Family Improvement

Information” (6H16-011).

※ The specifications and other items indicated herein are subject to change without notice.

※ All company and product names in this brochure are trademarks or registered trademarks.

Default Value

Communication

IP Address (Rack1) : 192.168.8.8

IP Address (Rack2) : 192.168.8.9

IP Address (Rack3) : 192.168.8.10

IP Address (Rack4) : 192.168.8.11

Port Number (All)

: 8888