OMRON

OMRON CP1E-NA20DT1-D PLC PLC

OMRON CP1E-NA20DT1-D PLC PLC

CJ1-H/CJ1M CPU Unit Ver. 2.0 Upgrades

The following table shows the functional upgrades for CJ1-H/CJ1M CPU Unit

Ver. 2.0.

Functional Upgrades for CJ1-H/CJ1M CPU Unit Ver. 2.0

Function

Downloading and Uploading Individual Tasks

Improved Read Protection Using Passwords

Write Protection from FINS Commands Sent to CPU Units via Networks

Online Network Connections without I/O Tables

Communications through a Maximum of 8 Network Levels

Downloading and Uploading Individual Tasks

Previous CPU Units (Pre-Ver. 2.0 CPU Units)

With the Pre-Ver. 2.0 CPU Units, individual program tasks could not be down

loaded from the CX-Programmer. It was only possible to download the entire

user program.

For example, if several programmers were developing the program, the

project manager had to unify each program after debugging and then down

load the entire user program. Furthermore, the entire user program had to be

downloaded even if just a few changes were made.

Note It was possible to upload individual program tasks with CS/CJ-series PLCs

When several programmers are developing a program, it isn’t necessary for a

project manager to unify the data because just the debugged tasks can be

downloaded/uploaded. Also, transferring individual tasks can help avoid mis

takes

CP1E-NA20DT1-D

Restrictions to Function

Block Use

When several programmers are developing a program, it isn’t necessary for a

project manager to unify the data because just the debugged tasks can be

downloaded/uploaded. Also, transferring individual tasks can help avoid mis

takes.

Developer A

CX-Programmer

Developer B

CX-Programmer

Developer C

CX-Programmer

Edited

Just the edited tasks can be downloaded.

Unchanged

Unchanged

Upload individual tasks.

CS/CJ-series

CPU Unit Ver.2.0 or later

Individual tasks cannot be downloaded for programs containing function

blocks (unit version 3.0 or later only) (uploading is possible).

1-6-2 Improved Read Protection Using Passwords

Read Protection for Individual Tasks Using Passwords

Previous CPU Units (Pre

Ver. 2.0 CPU Units)

CPU Unit Ver. 2.0 or Later

and CX-Programmer

Ver. 4.0 or Higher

5453-759 Woodward   TMR POWER SUPPLY CHASSIS
3HAC030826-001 ABB Motor incl pinion
3HAC17484-10 Rotational ac motor M8 ABB
MFC300-SYKL KROHNE MFC 300 Mass Flow   Converter
3HAC030829-001 ABB Motor incl pinion
PR6424/014-130 Eddy Current Signal   Converter EPRO
EASYGEN-3200XT 8440-2082 Woodward EasyGen   3000 series model
REF615E-1G ABB Feeder protection and   control
MVME162P-344SE Motorola Embedded   Controller
REF615 HBFKBCADNBA1BNN1XG Feeder   protection and control ABB
REF615 HBFJAEAGABC2BAA11G Feeder   protection and control ABB
PR6423/015-111 16mm Sensor EPRO
PXI-6255 NI PXI Multifunction I/O Module
REU610CVVHCNP01 ABB Voltage relay REU610
MXA81A-100-503-00 SEW motion axis   multi-axis servo inverter

With the pre-Ver. 2.0 CS/CJ-series CPU Units, it was possible to read-protect

the entire PLC with a password (referred to as “UM read protection” below),

but it was not possible to protect individual tasks.

UM read protection prevented anyone from displaying, editing, or uploading

the entire user program from CX-Programmer without inputting the correct

password.

Overview

With the CPU Unit Ver. 2.0 or later CPU Units, it is possible to read-protect

individual program tasks (referred to as “task read protection” below) or the

entire PLC. same password controls access to all of the read-protected tasks.

Task read protection prevents anyone from displaying, editing, or uploading

the read-protected set of tasks from CX-Programmer without inputting the cor

rect password. In this case, the entire program can be uploaded, but the read

protected tasks cannot be displayed or edited without inputting the correct

password. Tasks that are not read-protected can be displayed, edited, or mod

ified with online editing.

发表回复