OMRON CP1H-X40DT-D plc PLC
OMRON CP1H-X40DT-D plc PLC
This enables backup/restoration of all data in the CPU Unit including I/O com
ments if an error occurs or when adding a CPU Unit with the same specifica
tions without requiring a Programming Device.
1-5-5 Free-running Timers
The system timers used after the power is turned ON are contained in the fol
lowing Auxiliary Area words.
Name
10-ms Incrementing
Free Running Timer
Address
A000
Function
This word contains the system timer
used after the power is turned ON.
Access
Read-only
A value of 0000 hex is set when the
power is turned ON and this value is
automatically incremented by 1
every 10 ms. The value returns to
0000 hex after reaching FFFF hex
(655.350 ms), and then continues to
be automatically incremented by 1
every 10 ms.
(Unit version 3.0 or later)
100-ms Incrementing
Free Running Timer
A001

CP1H-X40DT-D
This word contains the system timer
used after the power is turned ON.
A value of 0000 hex is set when the
power is turned ON and this value is
automatically incremented by 1
every 100 ms. The value returns to
0000 hex after reaching FFFF hex
(6.553.500 ms), and then continues
to be automatically incremented by 1
every 100 ms.
(Unit version 3.0 or later)
1-s Incrementing Free
Running Timer
A002
This word contains the system timer
used after the power is turned ON.
A value of 0000 hex is set when the
power is turned ON and this value is
automatically incremented by 1
every second. The value returns to
0000 hex after reaching FFFF hex
(65.535 s), and then continues to be
automatically incremented by 1
every second.
(Unit version 4.0 or later)
1-5-6 New Special Instructions and Functions
The following new instructions and instruction functions have been added. For
details, refer to the CS/CJ Series Instructions Reference Manual (W340).
These new instructions are supported by the CX-Programmer Ver. 5.0 or
higher only.
• Serial Communications Instructions:
Supporting no-protocol communications with Serial Communications
Units with unit version 1.2 or later:
TXDU(256): TRANSMIT VIA SERIAL COMMUNICATIONS UNIT
RXDU(255): RECEIVE VIA SERIAL COMMUNICATIONS UNIT
Supporting no-protocol communications with Serial Communications
Boards with unit version 1.2 or later:
TXD(236): TRANSMIT
RXD(235): RECEIVE
• Model Conversion Instructions:
When using CX-Programmer Ver. 5.0 or higher to convert a C-series lad
der program for use in a CS/CJ-series CPU Unit, the C-series
XFER(070), DIST(080), COLL(081), MOVB(082), and BCNT(067)
instructions will be automatically converted to the following instructions.
The operands do not require editing.
XFERC(565) BLOCK TRANSFER
DISTC(566) SINGLE WORD DISTRIBUTE
COLLC(567) DATA COLLECT
MOVBC(568) MOVE BIT
BCNTC(621) BIT COUNTER
• High-speed Counter/Pulse Output Instructions (CJ1M Only):
High-frequency calculation methods have been added to the pulse fre
quency calculation methods for PRV(881) (HIGH-SPEED COUNTER PV
READ) and PRV2(883) (PULSE FREQUENCY CONVERT) instructions.
PRV(881) can also be used to read the pulse output frequency
| 1756-L72/B ControlLogix Controllers Allen Bradley |
| EP3-E-4-EN Controller module ALSTON |
| A06B-6220-H022H600 B FANUC MDL SVM1-130 SINGLE AXIS ALPHA SERVO DRIVE |
| PT-VME330B REV:B Performance 16 Port High Density/Low CostVME Communications Controller |
| MDX61B0030-5A3-4-00 SEW actuating motor |
| RMB-10V2-SYNQNET KOLLMORGEN Connect legacy analog drivers to SynqNet庐 systems |
| 5SDF0345D0006 Semiconductor thyristor ABB |
| MIFIIPA55E10HI00DC110-250V10W INTERFACE RELAY GE |
| PQMII-T20-C-DC90-300V-20VA PQM II Power Quality Meter GE |
| MIVI1000E00HI00 protective relay GE |
| 1756-L72K ControlLogix Controllers Allen Bradley |
| 2300/20-02-00 Bently Nevada 2300 Series Vibration Monitor |
| PLX82-EIP-61850 EtherNet/IP Server to PROFINET Controller Prosoft |
| 2301A-SC 9907-014 Woodward Load Sharing and Speed Control |
| A06B-6142-H055#H580 FANUC MDL SVM1-130 SINGLE AXIS ALPHA SERVO DRIVE |