OMRON

OMRON GRT1-TS2P  Temperature Module

OMRON GRT1-TS2P  Temperature Module

1. As shown above, there is no need to upgrade to CX-Programmer version

as long as the functions added for unit versions are not used.

2. CX-Programmer version 7.1 or higher is required to use the new functions

added for unit version 4.0 of the CJ1-H-R CPU Units. CX-Programmer ver

sion 7.22 or higher is required to use unit version 4.1 of the CJ1-H-R CPU

Units. CX-Programmer version 7.0 or higher is required to use unit version

4.2 of the CJ1-H-R CPU Units. You can check the CX-Programmer version

using the About menu command to display version information.

3. CX-Programmer version 7.0 or higher is required to use the functional im

provements made for unit version 4.0 of the CS/CJ-series CPU Units. With

CX-Programmer version 7.2 or higher, you can use even more expanded

functionality.

Device Type Setting

Series

CJ Series

GRT1-TS2P

CJ1-H CPU Units

The unit version does not affect the setting made for the device type on the

CX-Programmer. Select the device type as shown in the following table

regardless of the unit version of the CPU Unit.

The timing precision of version 4.0 and version 4.1 are different. Be sure

to check the effect on the application.

2. There have been no changes in the timing precision of TEN-MS TIMER in

structions (TIMH(015)/TIMHX(551)) and TENTH-MS TIMER instructions

(TIMU(541)/TIMUX(556)) since version 4.0. Use TEN-MS TIMER instruc

tions and TENTH-MS TIMER instructions if accuracy is a problem when

using HUNDRED-MS TIMER instructions and ONE-MS TIMER instruc

tions.

■ Programming Devices

Use CX-Programmer version 7.1 or higher for the CJ1-H-R CPU Units. Set

the device type to CJ1H-H and the CPU type to one of the CPU types ending

in “-R.” Use the following procedure.

1. Select New from the File Menu.

2. Select CJ1H-H in the Change PLC Dialog Box.

3. Select one of the following for the CPU type: CPU67-R, CPU66-R, CPU65

R, or CPU64-R.

Model

CJ1H-CPU67H-R

Device type

CJ1H-H

CPU type

CPU67-R

CJ1H-CPU66H-R

CJ1H-CPU65H-R

CJ1H-CPU64H-R

CPU66-R

CPU65-R

CPU64-R​

1. If CX-Programmer version 7.0 or lower is used, the new features of the

CJ1-H-R CPU Units will not be supported, i.e., functionality will be the

same as the CJ1-H CPU Units.

CX-Programmer version 7.22 or higher is required to use unit version 4.1

of the CJ1-H-R CPU Units. CX-Programmer version 7.0 or higher is re

quired to use unit version 4.2 of the CJ1-H-R CPU Units. CX-Programmer

version 7.22 or higher has added functionality that will provide a warning

when performing a program check or when transferring the program if a

ONE-MS TIMER instruction ((TMHH(540)/TMHHX(552)) is set to timer

numbers 0000 to 0015 or if a 0.01-second clock pulse is used. Version 7.22

or higher can be obtained using the auto-update function. If you are not

sure how to obtain CX-Programmer version 7.22. contact your OMRON

representative

KJ4001X1-NA1   12P3373X012 REV:C Horizontal LocalBus Dual Right Cable Extender EMERSON
KJ4001X1-NB1 12P3368X012 REV:E Horizontal   LocalBus Dual Left Cable Extender EMERSON
KJ4006X1-BD1 EMERSON S-Series Interface   Terminal Block
MELFA CR1-571 MITSUBISHI Q-TYPE   controller
PCD2.M110 servo controller SAIA
7CP476-010.9 B&R 2003 CPU with   expansion
SDCS-COM-81 3ADT314900R1002 POWER SUPPLY   ABB
MP904A5047 HONEYWELL Pneumatic Damper   Operators
BMXNRP0201 Schneider fiber converter   module
BMEP582040 Schneider M580 ePAC level 40   HSBY CPU
SB522V1 3BSC760015R1 ABB Battery unit for   AC400 Systems
4943013-6 ABB Backup Battery
PR6423/00R-010-CN+CON021 16mm Sensor EPRO
VMIVME-5565-110000 GE Reflective Memory   Node Card
PM3398B-6-1-3-E 80026-172-24 POWER SUPPLY   PIONEER MAGNETICS