OMRON GRT1-TS2P Temperature Module
OMRON GRT1-TS2P Temperature Module
1. As shown above, there is no need to upgrade to CX-Programmer version
as long as the functions added for unit versions are not used.
2. CX-Programmer version 7.1 or higher is required to use the new functions
added for unit version 4.0 of the CJ1-H-R CPU Units. CX-Programmer ver
sion 7.22 or higher is required to use unit version 4.1 of the CJ1-H-R CPU
Units. CX-Programmer version 7.0 or higher is required to use unit version
4.2 of the CJ1-H-R CPU Units. You can check the CX-Programmer version
using the About menu command to display version information.
3. CX-Programmer version 7.0 or higher is required to use the functional im
provements made for unit version 4.0 of the CS/CJ-series CPU Units. With
CX-Programmer version 7.2 or higher, you can use even more expanded
functionality.
Device Type Setting
Series
CJ Series

GRT1-TS2P
CJ1-H CPU Units
The unit version does not affect the setting made for the device type on the
CX-Programmer. Select the device type as shown in the following table
regardless of the unit version of the CPU Unit.
The timing precision of version 4.0 and version 4.1 are different. Be sure
to check the effect on the application.
2. There have been no changes in the timing precision of TEN-MS TIMER in
structions (TIMH(015)/TIMHX(551)) and TENTH-MS TIMER instructions
(TIMU(541)/TIMUX(556)) since version 4.0. Use TEN-MS TIMER instruc
tions and TENTH-MS TIMER instructions if accuracy is a problem when
using HUNDRED-MS TIMER instructions and ONE-MS TIMER instruc
tions.
■ Programming Devices
Use CX-Programmer version 7.1 or higher for the CJ1-H-R CPU Units. Set
the device type to CJ1H-H and the CPU type to one of the CPU types ending
in “-R.” Use the following procedure.
1. Select New from the File Menu.
2. Select CJ1H-H in the Change PLC Dialog Box.
3. Select one of the following for the CPU type: CPU67-R, CPU66-R, CPU65
R, or CPU64-R.
Model
CJ1H-CPU67H-R
Device type
CJ1H-H
CPU type
CPU67-R
CJ1H-CPU66H-R
CJ1H-CPU65H-R
CJ1H-CPU64H-R
CPU66-R
CPU65-R
CPU64-R
1. If CX-Programmer version 7.0 or lower is used, the new features of the
CJ1-H-R CPU Units will not be supported, i.e., functionality will be the
same as the CJ1-H CPU Units.
CX-Programmer version 7.22 or higher is required to use unit version 4.1
of the CJ1-H-R CPU Units. CX-Programmer version 7.0 or higher is re
quired to use unit version 4.2 of the CJ1-H-R CPU Units. CX-Programmer
version 7.22 or higher has added functionality that will provide a warning
when performing a program check or when transferring the program if a
ONE-MS TIMER instruction ((TMHH(540)/TMHHX(552)) is set to timer
numbers 0000 to 0015 or if a 0.01-second clock pulse is used. Version 7.22
or higher can be obtained using the auto-update function. If you are not
sure how to obtain CX-Programmer version 7.22. contact your OMRON
representative
| KJ4001X1-NA1 12P3373X012 REV:C Horizontal LocalBus Dual Right Cable Extender EMERSON |
| KJ4001X1-NB1 12P3368X012 REV:E Horizontal LocalBus Dual Left Cable Extender EMERSON |
| KJ4006X1-BD1 EMERSON S-Series Interface Terminal Block |
| MELFA CR1-571 MITSUBISHI Q-TYPE controller |
| PCD2.M110 servo controller SAIA |
| 7CP476-010.9 B&R 2003 CPU with expansion |
| SDCS-COM-81 3ADT314900R1002 POWER SUPPLY ABB |
| MP904A5047 HONEYWELL Pneumatic Damper Operators |
| BMXNRP0201 Schneider fiber converter module |
| BMEP582040 Schneider M580 ePAC level 40 HSBY CPU |
| SB522V1 3BSC760015R1 ABB Battery unit for AC400 Systems |
| 4943013-6 ABB Backup Battery |
| PR6423/00R-010-CN+CON021 16mm Sensor EPRO |
| VMIVME-5565-110000 GE Reflective Memory Node Card |
| PM3398B-6-1-3-E 80026-172-24 POWER SUPPLY PIONEER MAGNETICS |