OMRON

Omron NX1P2-1140DT-BA Programmable Controller

Omron NX1P2-1140DT-BA Programmable Controller

Sysmac NX1P CPU with 40 Digital Transistor I/O (NPN), 1.5 MB memory, EtherCAT (4 servo axes, 4 PTP axes, 16 EtherCAT nodes), EtherNet/IP and 2 serial option ports

Special function    NX Local Bus

Program capacity    1.5 MB

I/O capacity    296 points local (808 with NX Coupler)

Maximum number of units    8 Local IO Units; 24 total per CPU

Flash memory port    SD

Total Axes/Point to Point Axes/Coordinated Axes    8/4/4

Min Cycle Time    2 ms

Motion Control Network    EtherCAT

Programming language    Ladder / Structured Text / Function Block

Communication ports    EtherCAT and EtherNet/IP built in

Programming Connection    Ethernet

Mounting    DIN Rail

Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1

Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.

Analog input: ±0.2% FS ±1 digit max.

CT input: ±5% FS ±1 digit max.

NX1P2-1140DT-BA

Potentiometer input: ±5% FS ±1 digit max.

Transfer output accuracy ±0.3% FS max.

Remote SP Input Type ±0.2% FS ±1 digit max.

Influence of temperature *2 Thermocouple input (R, S, B, C/W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max.

Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *3

Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

Analog input: ±1%FS ±1 digit max.

CT input: ±5% FS ±1 digit max.

Remote SP  input: ±1% FS ±1 digit max.

Influence of voltage *2

Influence of EMS.

(at EN 61326-1)

Input sampling period 50ms

Hysteresis Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or°F)

Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P) Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I) Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)

Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s)*4

Derivative time (D) 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period 0.1. 0.2. 0.5. 1 to 99 s (in units of 1 s)

Manual reset value 0.0 to 100.0% (in units of 0.1%)

Alarm setting range-1999 to 9999 (decimal point position depends on input type)

Influence of signal source

resistance

Thermocouple: 0.1°C/Ω max. (100 Ω max.)

Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

Insulation resistance 20 MΩ min. (at 500 VDC)

Dielectric strength 3.000 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

Resistance 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock Malfunction 100 m/s2. 3 times each in X, Y, and Z directions

Resistance 300 m/s2. 3 times each in X, Y, and Z directions

Weight E5EC/E5EC-B: Controller: Approx. 210 g, Mounting Adapter: Approx. 4 g × 2

E5AC: Controller: Approx. 250 g, Mounting Adapter: Approx. 4 g × 2

Degree of protection Front panel: IP66. Rear case: IP20. Terminals: IP00

Memory protection Non-volatile memory (number of writes: 1.000.000 times)

Setup Tool E5EC/E5AC: CX-Thermo version 4.5 or higher

E5EC-B: CX-Thermo version 4.65 or higher *9

Setup Tool port

E5EC/E5EC-B/E5AC top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a

USB port on the computer.*5

E5EC/E5EC-B/E5AC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion

Cable are used together to connect to a USB port on the computer.*5

Standards Approved standards cULus: UL 61010-1/CSA C22.2 No.61010-1. Korean wireless regulations (Radio law: KC Mark) (Some