OMRON

OMRON SGMPH-04AAA61D-OY Servo Motor

USB-Serial Conversion Cable

Applicable OS

Windows XP/Vista/7/8/10 *1

Applicable software CX-Thermo version 4.62 or higher

Applicable models

E5@C-T Series, E5@C Series, and E5CB Series

USB interface standard Conforms to USB Specification 2.0

DTE speed

Connector

specifications

Power supply

38.400 bps

Computer: USB (Type A plug)

Digital Temperature Controller: Special serial

connector

Bus power (Supplied from the USB host controller)  *2

Power supply voltage 5 VDC

Current

consumption

Output voltage

Output current

Ambient operating

temperature

Ambient operating

humidity

450 mA max.

4.7±0.2 VDC (Supplied from USB-Serial Conversion

Cable to the Digital Temperature Controller.)

250 mA max. (Supplied from USB-Serial Conversion

Cable to the Digital Temperature Controller.)

0 to 55°C (with no condensation or icing)

10% to 80%

Storage temperature −20 to 60°C (with no condensation or icing)

Storage humidity

10% to 80%

Altitude

Weight

2.000 m max.

Approx. 120 g

Windows is a registered trademark of Microsoft Corporation in the

United States and or other countries.

*1.CX-Thermo version 4.65 or higher runs on Windows 10.

*2.Use a high-power port for the USB port.

Note: A driver must be installed on the computer. Refer to the Instruction

Manual included with the Cable for the installation procedure.

Communications Specifications

Transmission line

connection method

Communications

RS-485: Multidrop

RS-485 (two-wire, half duplex)

Synchronization method Start-stop synchronization

Protocol

Component

Communi

cations

Copying *

When Digital Temperature Controllers are connected,

set points and RUN/STOP commands can be sent

from the Digital Temperature Controller that is set as

the master to the Digital Temperature Controllers that

are set as slaves.

Slope and offsets can be set for the set point.

Number of connected Digital Temperature

Controllers: 32 max. (including master)

When Digital Temperature Controllers are connected,

the parameters can be copied from the Digital

Temperature Controller that is set as the master to the

Digital Temperature Controllers that are set as slaves.

MELSEC is a registered trademark of Mitsubishi Electric Corporation.

KEYENCE is a registered trademark of Keyence Corporation.

*Both the programless communications and the component

communications support the copying.

Current Transformer (Order Separately)

Ratings

E54-CT1

E54-CT3

E54-CT1L

E54-CT3L

Dielectric strength 1.000 VAC for 1 min

Vibration resistance

1.500 VAC for 1 min

50 Hz, 98 m/s2

Weight

Accessories

E54-CT1: Approx. 11.5 g

E54-CT3: Approx. 50 g

E54-CT3 Only

Armatures (2)

Plugs (2)

E54-CT1L: Approx. 14 g

E54-CT3L: Approx. 57 g

None

Heater Burnout Alarms and SSR Failure

Alarms

CT input (for heater

current detection)

Models with detection for single-phase

heaters: One input

Maximum heater current 50 A AC

Input current

indication accuracy

±5% FS ±1 digit max.

Heater burnout alarm

setting range *1

CompoWay/F, or Modbus

Baud rate *

Transmission code

9.600. 19.200. 38.400. or 57.600 bps

ASCII

SSR failure alarm setting

range *2

0.1 to 49.9 A (in units of 0.1 A)

Minimum detection ON time: 100 ms *3

Data bit length *

Stop bit length *

Error detection

Flow control

Interface

Retry function

7 or 8 bits

1 or 2 bits

Vertical parity (none, even, odd)

Block check character (BCC)

with CompoWay/F or

CRC-16 with Modbus

None

RS-485

None

0.1 to 49.9 A (in units of 0.1 A)

Minimum detection OFF time: 100 ms

*4

*1.For heater burnout alarms, the heater current will be measured

when the control output is ON, and the output will turn ON if the

heater current is lower than the set value (i.e., heater burnout

detection current value).

*2.For SSR failure alarms, the heater current will be measured when

the control output is OFF, and the output will turn ON if the heater

current is higher than the set value (i.e., SSR failure detection

current value).

*3.The value is 30 ms for a control period of 0.1 s or 0.2 s.

*4.The value is 35 ms for a control period of 0.1 s or 0.2 s.

Communications buffer

Communications

response wait time

217 bytes

0 to 99 ms

Default: 20 ms

*The baud rate, data bit length, stop bit length, and vertical parity can

be individually set using the Communications Setting Level.

Communications Functions

Programless

communica

tions

10

You can use the memory in the PLC to read and write

E5@C parameters, start and stop operation, etc.

The E5@C automatically performs communications with

PLCs. No communications programming is required.

Number of connected Digital Temperature

Controllers: 32 max. (Up to 16 for the FX Series)

Applicable PLCs

OMRON PLCs

CS Series, CJ Series, CP

Series, NJ Series, or NX1P

Mitsubishi Electric PLCs MELSEC Q Series, L Series,

FX3 Series, or iQ-R Series

KEYENCE PLCs

KEYENCE KV Series​