GE ALSTOM BP-1 Backplane (Colorlight / Repeater Cabinet)
RP2000
In this mode the controller will communicate with the remote unit using RP2000. RP2000 messages are
sent continually whether or not the message contents have changed. RP2000 an be used on serial point-to
point connections, serial multi-drop connections, serial-to-Ethernet connes, direct Ethernet
connections, and Radio links.
RP2000 with RP1992 Fallback
In this mode the controller will start remote communications using theRP2000 protocol. If it detects thatthe
remote unit is communicating using the RP1992 protocol, the controller will switch to the RP1992protocol
to enable it to communicate with the remote unit. RP1992 can only be used ard-wired pointto point
networks where it is impossible for remote messages to be receeived out of order
RP2009
In this mode the controller will communicate with the remote unit using RF2009. When using RP2009.
messages are not sent continually. Rather, messages are only sent when:
1) the message contents changes,
2) a Heartbeat Message Interval (HMI) time has elapsed since the last message was sent, or
3) in acknowledgement of receiving a message from a remote device
RP2009 can be used on serial connections, serial-to-Ethernet connections, ct Ethernet connections, and
Radio links. RP2009 does not support serial multi-drop conneetions
Positive Train Control EMP Class D
In this mode the controller will communicate with other PTC enablednodes to receive Locomotive Request
messages and send PTC mapped Wayside Interface Unit (WIU) statuises.
Positive Train Control ACSES
In this mode the controller will communicates with other ACSES enabled nodes to receive Signal Status
Request messages and send corresponding Signal Status messages based onWayside Interface Unit
(WIU) statuses.
VPM-2/VPM-2+ Vital Peripheral Master Module
VPM-2:P/N:251135-000
VPM-2+:P/N:251395-000
The VPM-2/VPM-2+ is a microprocessor-based module comprised of three CPUs (A, B, and C) that
control the operation of the ElectroLogIXS/EC5 system. The VPM-2/VPM-2/VPMcontains
ElectroLogIXS/EC5 executive software that is common to all VPM-22/VPM-2+ based
ElectroLogIXS/EC5products. The VPM-2/VPM-2/VPM-2+ is responsible for downlading the application
EPROM and running the application vitally along with maintaining system saty checks and providing
diagnostic features.
CPU A and CPU B
CPU A and CPU B are responsible for the system’s vital application logic pssing, communication, and
control of the installed ElectroLogIXS/EC5 I/O modules, and the continual performance of the system
safety checks
User supplied configuration information such as track and lamp settings,vital configuration settings, etc.
are used by CPU A and CPUB during application program execution and are vitally stored in non-volatile
memory on the ElectroLogIXS/EC5 backplane. All modules, with the exceptionof the CI and backplane
modules may be replaced without loss of the system configuration information
CPU C
CPU C is the processor primarily responsible for the ElectroLogIXS/EC5 system diagnostics and user interface.
CPU C provides the communication control interface for the CDU or C!Modules. CPU C also maintains
system wide, non-volatile diagnostic logging in the Error, Recorder, Cormmunication, and Configuration logs.
The non-vital configuration settings, such as baud rates, port settings, ec. are maintained by CPU C and are
stored in non-volatile memory on the ElectroLogIXS/EC5 backpplane.
I/O Module Interface
The VPM-2/VPM-2+ contains an interface by which the CPU A and CPUB can communicate with all of
the I/O modules. The VPM-2/VPM-2+ acts as a master while all of the I/O modules in the
ElectroLogIXS/EC5 product family act as slave modules.
Cl Interface
The CI-1 or XCI-1 Interface is the means by which the VPM-2/VPM-2+ retrievthe application
programfrom the CI-1 or XCI-1 module.
CDU Interface
The CDU connector on the front of the VPM-2/VPM-2+ (see Figure 1-7provides the communicationpath
between the CPU C and the CDU-1 or CDU-2.