ALSTOM

ALSTOM ZP006000XX CPU Mainboard

RP2000

In this mode the controller will communicate with the remote unit using RP2000. RP2000 messages are

sent continually whether or not the message contents have changed. RP2000 an be used on serial point-to

point connections, serial multi-drop connections, serial-to-Ethernet connes, direct Ethernet

connections, and Radio links.

RP2000 with RP1992 Fallback

In this mode the controller will start remote communications using theRP2000 protocol. If it detects thatthe

remote unit is communicating using the RP1992 protocol, the controller will switch to the RP1992protocol

to enable it to communicate with the remote unit. RP1992 can only be used ard-wired pointto point

networks where it is impossible for remote messages to be receeived out of order

RP2009

In this mode the controller will communicate with the remote unit using RF2009. When using RP2009.

messages are not sent continually. Rather, messages are only sent when:

1) the message contents changes,

2) a Heartbeat Message Interval (HMI) time has elapsed since the last message was sent, or

3) in acknowledgement of receiving a message from a remote device

RP2009 can be used on serial connections, serial-to-Ethernet connections, ct Ethernet connections, and

Radio links. RP2009 does not support serial multi-drop conneetions

Positive Train Control EMP Class D

In this mode the controller will communicate with other PTC enablednodes to receive Locomotive Request

messages and send PTC mapped Wayside Interface Unit (WIU) statuises.

Positive Train Control ACSES

In this mode the controller will communicates with other ACSES enabled nodes to receive Signal Status

Request messages and send corresponding Signal Status messages based onWayside Interface Unit

(WIU) statuses.

VPM-2/VPM-2+ Vital Peripheral Master Module

VPM-2:P/N:251135-000

VPM-2+:P/N:251395-000

The VPM-2/VPM-2+ is a microprocessor-based module comprised of three CPUs (A, B, and C) that

control the operation of the ElectroLogIXS/EC5 system. The VPM-2/VPM-2/VPMcontains

ElectroLogIXS/EC5 executive software that is common to all VPM-22/VPM-2+ based

ElectroLogIXS/EC5products. The VPM-2/VPM-2/VPM-2+ is responsible for downlading the application

EPROM and running the application vitally along with maintaining system saty checks and providing

diagnostic features.

CPU A and CPU B

CPU A and CPU B are responsible for the system’s vital application logic pssing, communication, and

control of the installed ElectroLogIXS/EC5 I/O modules, and the continual performance of the system

safety checks

User supplied configuration information such as track and lamp settings,vital configuration settings, etc.

are used by CPU A and CPUB during application program execution and are vitally stored in non-volatile

memory on the ElectroLogIXS/EC5 backplane. All modules, with the exceptionof the CI and backplane

modules may be replaced without loss of the system configuration information

CPU C

CPU C is the processor primarily responsible for the ElectroLogIXS/EC5 system diagnostics and user interface.

CPU C provides the communication control interface for the CDU or C!Modules. CPU C also maintains

system wide, non-volatile diagnostic logging in the Error, Recorder, Cormmunication, and Configuration logs.

The non-vital configuration settings, such as baud rates, port settings, ec. are maintained by CPU C and are

stored in non-volatile memory on the ElectroLogIXS/EC5 backpplane.

I/O Module Interface

The VPM-2/VPM-2+ contains an interface by which the CPU A and CPUB can communicate with all of

the I/O modules. The VPM-2/VPM-2+ acts as a master while all of the I/O modules in the

ElectroLogIXS/EC5 product family act as slave modules.

Cl Interface

The CI-1 or XCI-1 Interface is the means by which the VPM-2/VPM-2+ retrievthe application

programfrom the CI-1 or XCI-1 module.

CDU Interface

The CDU connector on the front of the VPM-2/VPM-2+ (see Figure 1-7provides the communicationpath

between the CPU C and the CDU-1 or CDU-2.