ALSTOM ZP004000XX Analog Input Acquisition Board
ElectroLogIXS Chassis
The open-frame ElectroLogIXS chassis allows easy access to all modulles and plug in connections.
Mounted in the back of the chassis is a one piece backplane
that provides interconnections to all the modules of the
ElectroLogIXS system. Personality modules (Figure 1-3)
attach to the backplane and connect the modules to the field
wiring. Quick disconnect clips secure modules to the chassis
and all personality module connectors are keyed to insure that
modules are placed into the correct slot. In addition, the
personality module field wiring connectors are keyed.
I/O module slots can include: :
XTI-1S modules
VIO-44S modules
VIO-44R modules
IXC-20S modules
VTI-2S modules
VIO-1010S modules
VIO-86S modules
VIO12-86S modules
VIO24-86S modules
VIO50-86S modules
VIO-88 Modules
VLD-C6S modules
VLD-R16S modules
VLD-R8AC/ VLD-R8AC12 modules
CAB-16S modules
VTI-2E modules
System module slots can include:
CPS-2 or CPS-3 module
NSM-1 module
VPM-2+ or VPM-3 module
GFD-1 module
CIO-1A module,CIO-CLA module
CIO-2A module, CIO-2AB module
CIO-MDA module
CIO-PCA module
EC5 Physical Description
The EC5 may be received as a separate assembly or as part of preassembled rack. It is designed for
mounting in a standard 19-inch rack, wall mounting, or installaticon on a shelf. Operating power is
supplied from a standard 12 volt battery. The battery terminals are conveniently located in the upper left
corner of the EC5 motherboard, and are labeled N (negative) and B (battery positive)
The EC5 consists of a chassis assembly and several plug-in modules. Theleft side of the chassis contains
four card slots that are dedicated for the Central Power Supply (CPS-1), Vital Peripheral Master (VPM-2+
or VPM-3) Module, Chassis Information (CI-1. CI-2 or UCI-3) Module, and the Communication Input
Out (CIO-1 or CIO-CLA) Module. One additional slot is available and it vvill accommodate a CIO-2.
CIO-3. CIO-MDA module.
The right side of the chassis has four module I/O slots. The following modbe installed in the I/O
slots: VLD-C6S (Vital Lamp Driver), VTI-2S (Vital Track Interface), VTI-2E (Vital Track Interface),
VIO-1010S (Track Code Select Input Track Code Decoder Output), or VIO-44S ital Input/Output). Up
to two slots may be used for VLD-C6S or VIO-1010S Modules,depending on the application.
The open-frame EC5 chassis allows easy access to all of the modules and plug in connections. Mounted in
the back of the chassis is a one-piece backplane that provides interconnecons to all of the modules of the
EC5system. Quick disconnect clips secure modules to the chassis and all comectors are keyed to insure
that modules are placed into the correct slot.