ALSTOM SZ50007730 Power Module
Electro Code 6 (EC6)
Next Generation Track Circuit
Customer Benefits
Simple Upgrade
■ No changes to application software required (if not using additional codes/statuses)
■ Replace the VTI-2S module with the VTI-2E module – PN 251777-200 supports legacy Electro Code and the new EC6 protocol – PN 251777-300 supports legacy Electro Code, the new EC6 protocol, and Virtual Block
■ Upgrade the executive software to version 6.42 or newer
■ Upgrade or replace the Track Inductor Panel to be compatible with EC6 – TIP upgrade kit for EC6 (PN 180756-000) – For new installations, use TIP-2E (PN 800-096000-7
About the Technology
The EC6 uses advanced signal processing techniques to provide a digital vital communication through
the rails. The communication is designed such that it will not interfere with other track connected
devices such as highway grade crossings, cab signal systems, and audio overlays.
The digital communications allows for an increase in the amount of data that can be transmitted
between wayside locations. It also allows for each location to share information with each other
regarding how much signal is transmitted and received, which enables real-time measurement of
ballast conditions. Knowledge of the ballast conditions has not traditionally been known and is useful
for understanding the overall health of the track.
This innovative approach to track circuit design, in some cases, allows for operation at lower ballast
conditions. It also allows for better detection of poor shunting vehicles.
EC6 allows the user to insert Application Defined Statuses into the digital communications. This can
be useful for propagating custom information through the rails such as maintenance alerts, switch
position, crossing alarms, etc.
Unlike when migrating from EC4. existing EC5 and ElectroLogIXS installations do not need to be
replaced but can be easily upgraded to utilize EC6 track protocol. Many of the benefits can be realized
with a simple module swap (VTI-2E for VTI-2S), replacement of the lightning protection and fuses on
the Track Inductor Panel (TIP upgrade kit for EC6), and a VPM-3 executive software upgrade, without
any changes to existing application software or wiring. To use EC6 Application Defined Statuses, Track
Codes A-H, or VTI-2E NVIO requires an application compiled in LogicStation revision 2.13 or newer.
For more information regarding which VPM-3 executive software versions support EC6. contact KB
Signaling