Keba RS 091 I RS-091 Power Supply Module 21214 I 2055D-0 Vers. D1.0
Analog inputs (differential or single-ended)
Number of inputs 8
Type Voltage input
Input type Differential (standard setting) or single-ended; freely assignable via software
Signal range Differential: ±10 V; single-ended: 0 – Uref
Reference voltage output Uref 10 V ±2.5 %, max. 20 mA
Max. measurement signal-10.4 V … +10.4 V
Galvanic isolation of the output groups No
Galvanic isolation from the control electronics No
Sensor failure detection Yes
Scan repeat cycle 100 μs
Input impedance in signal range 5 MΩ
Input filter characteristic – order Second order
Input filter transfer frequency 2500 Hz
Digital filters Configurable to: no filter, 500 μs, 1 ms, 5 ms
Resolution 16 bit (±10 V), 15 bit (0 V – Uref)
Conversion method Successive approximation
Monotonicity without error codes Yes
Common mode range ±13.5 V
Common mode rejection ratio > 80 dB
Value of the lowest bit (LSB) 0.325 mV
Maximum permitted continuous load
(without damage) ±30 V
Typ. temp. coefficient measurement error ±5 ppm of scale end value / °C
Max. temp. coefficient measurement error ±20 ppm of scale end value / °C
Largest error at 25 °C ±0.02 % of scale end value
Analog outputs
Number of outputs 6
Type Voltage output
Signal range ±10 V
Galvanic isolation of the output groups No
Galvanic isolation from the control electronics No
Permanently short-circuit proof Yes
Conversion cycle 100 μs
Digital resolution 12 bit
Value of the lowest bit (LSB) 5.22 mV
Monotonicity Yes
Load resistance ≥ 1000 Ω
Largest capacitive load ≤ 10 nF
| SCHNEIDER | RXZE1M114M |
| SCHNEIDER | SDC40 |
| SCHNEIDER | STBAVO0200 |
| SCHNEIDER | STBDAI7220 |
| SCHNEIDER | STBDAO8210 |
| SCHNEIDER | TCSESM043F2CS0 |
| SCHNEIDER | TFTX11702 |
| SCHNEIDER | TM258LD42DT |
| SCHNEIDER | TSX07301012 |
| SCHNEIDER | TSX07301028 |
| SCHNEIDER | TSX07311612 |
| SCHNEIDER | TSX07311622 |
| SCHNEIDER | TSX07311628 |
| SCHNEIDER | TSX07311648 |
| SCHNEIDER | TSX07312422 |
Settling time when changing over the full range ≤ 100 μs
Typ. temp. coefficient analog output error ±20 ppm of scale end value / °C
Max. temp. coefficient analog output error ±30 ppm of scale end value / °C
Largest error at 25 °C ±0.15 % of scale end value
Temperature inputs J, K, L, N
Number of inputs 8
Galvanic isolation Yes, from the control electronics and between one another
Electric strength 500 V AC
Sensor failure detection Yes, underflow
Thermoelement types J, K, L, N
Measurement ranges
Type J (Fe-CuNi): -100 °C … +700 °C
Type K (NiCr-Ni): -100 °C … +1000 °C
Type L (FeCu-Ni): -100 °C … +700 °C
Type N (NiCrSi-NiSi): -100 °C … +1000 °C
Measurement principle Integrated
Measurement interval Configurable: 20 / 40 / 100 ms
Mains frequency Configurable: 50 / 60 Hz
Input resistance 10 MΩ
Maximum resistance value
of the thermoelement 50 Ω
Resolution of the measurement process 16 bit
Connections Pluggable connection terminals pitch 5.08. gold-plated contacts
Intrinsic deviation ±2.5 °C max. absolute measurement deviation over the entire measurement range (±0.5 °C
typical), at 25 °C ambient temperature at the module
Operational deviation
±1 % of measurement value or ±2.5 °C absolute. The larger of the two values applies.
Absolute measurement deviation under reference conditions: Ambient temperature of the modu
le between 0 °C and 55 °C, temperature measurement range between 0 °C and 500 °C
Precision of terminal temperature sensor ±1 °C max. absolute measurement deviation at 0 °C to 70 °C ambient temperature (±0.5 °C
typical)
Precision with internal
terminal temperature compensation ±2 °C after 30 minutes, with natural convection
Precision with external compensation
with TE 220/A
With the optimized positioning of the external sensor (TE 220/A), the error can be minimized to
±0.5 °C (typical) through terminal temperature compensation
Thermal settling time After 15 – 30 minutes, the measurement result is stable and within the specified tolerances
EtherCAT interface
Number 2
Data transmission rate 100 Mbit/s
K-bus interface
Function for the direct connection of K-bus modules