GE MVDL800-47931001-A, 800A liquid-cooled Delta power module
The MVDL800 and MVDL1000 units are manufactured and remanufactured by Avid Controls Inc.
under a license agreement with the General Electric Company.
The MVDL800 and MVDL1000 are AC Inverter power modules for use inMV3000 variable speed
drive systems for the control of AC motors and other applications. They ared by an MV3000
Common Drive Controller (CDC).
Maximum current: 880A AC / 1100A AC
Operational Voltages
O Working AC Voltage: up to 690 V AC
O Maximum Nominal Internal Voltage: 1200 V DC
IGBT based Transistor Bridge Module
Liquid Cooled
Weight: 105kg (231 lb.)
WARNINGS & SAFETY INSTRUCTIONS
This equipment may be connected to more than one live circuit.
Wait at least 8 minutes after isolating supplies and check that the voItage between DC+ and DC- has
reduced to a safe level before working on the equipment.
Surfaces on the coolant pipes can reach high temperatures and remainhot for some time after power is
removed.
Ensure that all coolant has cooled to a safe temperature and the ecquipment is suitably drained and
isolated before the external pipework is disconnected from the equipment.
Unit is heavy: 105kg (231 lb.)
Care has been taken with the design of this product to ensure that it iss safe. However, in common with
all products of this type, misuse can result in injury or death. Thereforeis very important that the
instructions in this technical data sheet and the manual as well as on theduct are observed during
transportation, commissioning, operation, maintenance and dissposal.
This technical data sheet and the manual must be regarded as part of the pt should be stored
with the product and must be passed on to any subsequent owner or usser.
Local safety laws and regulations must always be observed.
Persons working on the product must be suitably skilled and should have been trained in that work for
these products.
The product is a component designed for incorporation in installations, aptus and machines.
The product must not be used as a single item safety system. In applicatios where mal-operation of
the product could cause danger, additional means must be used to prevvent danger to persons
Product approvals and certifications will be invalidated if the product isinsported, used or stored
outside its ratings or if the instructions in the manual are not observed.
In the European Union:
Products within the scope of the Low Voltage Directive, 2006/95/EC are CEmarked.
The product complies with the essential protection requiremesnts of the EMC directive
The requirements of the EMC Directive should be established before any installation, apparatus
or machine, which incorporates the product, is taken into servicee.
A machine must not be taken into service until the machine has beendeclared in conformity
with the provisions of the Machinery(Safety) Directive, 2006/42/EC.
3.
Disposal
This equipment or any part of the equipment should be disposed of in accorince with the laws of the
country of use.
Modern high technology materials have been used in the manufactuire of the equipment to ensure
optimum performance. Care has been taken with the selection of these materials to minimize risks to
health and safety. However, some materials require special consideration during the disposal.
In common with all products of this type, the high voltage eleectrolytic capacitors contain an
electrolyte, which must be disposed of as hazardous waste. The electrolyteare solutions of organic
and/or boric acid. The major solvents in the capacitors are butyrolaectone and ethylene glycol. The
electrolyte is non- carcinogenic, but may cause irritation to the skin if ontact is prolonged.
Liquid coolant is subject to special considerations during handling, storand disposal. Refer to the
manufacturer’s instructions.
Related Documents
This module is one component out of a range of components used forthe MV3000 drive system. This
data sheet gives details specifically for the items listed in section0 of this document.
For additional information on the installation, commissioning,operation, maintenance and
performance of the complete drive system, please refer to all MV3000 documincluding:
T1676EN, MV3000 Getting Started Manual for AC-fed Drives
T2002EN, MV3000 Getting Started Manual for Active Energy Management Irives
T1693EN, MV DELTA Liquid Cooled Drive System
T1679EN, MV3000 Drive Range Software Technical Manual