Triconex Model 3401 Digital Output Module
RG 1.180 termination panels are suitable for use in applications that need to meet the
requirements of Regulatory Guide 1.180. “Guidelines for Evaluating Electromagnetic and
Radio-Frequency Interference in Safety-Related Instrumentation and Control Systems, Revision
1” published by the U.S. Nuclear Regulatory Commission.
Hazardous Location (Nonincendive) Termination Panels
Hazardous location (nonincendive) termination panels are suitable for use in Zone 2. and Class
1. Division 2 field circuits. These panels contain extra circuitry designed to limit power available
to the field terminals and have been examined and certified by TÜV Rheinland as being
nonincendive. This guarantees that if the field wires are accidentally opened, shorted, or
grounded, and the Tricon is operating normally, the wiring and attached devices will not
release sufficient energy to cause ignition in the specified flammable atmosphere.
Termination Panels with Interposing Relays
Termination panels with interposing relays can be used with most digital output modules and
are recommended for these applications:
• Load currents greater than 2 amps
• Field voltages greater than 115 VAC
• Voltage-level conversions
• Motor-starter circuit compatibility
Interposing relay panels are available in these configurations:
• 16-point c
ommoned
• 16-point non-commoned
The digital outputs of the interposing relays are not fault-tolerant. However, each relay
provides an auxiliary contact that can be fed into a digital input to send a loopback signal to the
control program. A user-written loopback check in the control program can ensure that the relay
has achieved its commanded state. The loopback cable must be ordered separately.
Each interposing relay panel provides the capability to common power and return through a
factory-mounted bus-bar arrangement.
Each interposing relay panel consists of:
• A 7 in x 19 in (36 cm x 48 cm) rack-mountable panel with terminals for 16 digital
outputs and 16 digital inputs.
• Two ELCO connectors mounted on the panel for connecting to digital input modules
using digital input cables 9141-010. 9142-010. or 9143-010.
• An EIA standard RS-310-C plate on which the termination panel is mounted.
• A digital output module and a cable compatible with the selected coil voltage.
Tricon and Tricon CX High-integrity + high-availability system
The TriconTM high-integrity/high-availability system meets the needs of safety and critical
control applications in oil and gas, power, refining, chemicals, pharmaceutical, and biotech industries.
It is based on industry-leading TMR technology, is easy to operate and maintain, and provides a higher value of ownership.
SAFE • AVAILABLE • SECURE
Schneider ElectricTM is the only automation
company with the experience and track
record in safety and critical control with
more than 30 years of safety system
experience. It is also the only automation
company with more than 13.000 safety
systems installed in more than 80 countries
and operating for more than 1 billion hours.
TRICONEX TRIPLE MODULAR REDUNDANCY
Tricon operation is based on the principle of safety and high plant availability, which identifies and
compensates for failed control system elements and allows on line replacement while continuing
its assigned task without interrupting the controlled process. Fault Tolerance is achieved through TMR technology.
TMR employs three isolated, parallel control systems and extensive diagnostics integrated into one
system. The Tricon system uses two-out-of-three (2oo3) voting to provide high integrity, error-free,
uninterrupted process operation with no single point of failure. Setting up applications is simplified
with the Tricon, because the TMR system operates as a single control system from the user’s point of
view. The extensive diagnostics are inherent and transparent to the programmer.
Use of the Tricon continues to expand into new industries and applications as customers require
increased system safety and/or high availability. Today, Invensys has delivered and installed Triconex
safety system solutions in over 70 countries, providing increased safety and high process uptime.
Managing operational risks with confidence
The Tricon fail-safe and fault-tolerant controller is used extensively in high-hazard industries
where safe operations are critical and reliable operation is paramount.
In particular, the Tricon system is the only commercial off-the-shelf controller approved by
the Nuclear Regulatory Commission for Nuclear 1E applications.
Our safety and critical control solutions are supported by a dedicated team of TÜV-certified FunctionalSafety Experts and Engineers,
deplo yed globally, ensuring that expertise is always available where and when required.
A powerful, scalable design with assurance of continuous operation,
the Tricon system complies with international standards such as IEC61508 and fulfills
the requirements for applications such as Emergency Shutdown (ESD), Fire and Gas Protection (F&G),
Burner Management (BMS),High Integrity Pressure Protection (HIPPS), and Turbo Machinery Control (TMC).
The redundant high-availability architecture provides a flexible,robust, reliable,
and powerful solution that is ideal for clients looking to achieve environmental and safety excellence