Triconex

Triconex Model 2292 VO Extender Module Kit

ENSURING OPERATIONAL CONTINUITY AND MANAGING OPERATIONAL RISKS

Invensys is the only automation company with the experience and

track record in safety and critical control as demonstrated by our 27

years of experience in safety systems,in excess of 8.000 installed systems,

the only approved Nuclear Regulatory Commission Commercial off-the-shelf controller

for Nuclear 1E applications,large number of TÜV certified Functional Safety Experts and Engineers,

deployed world wide, and patented Triple Modular Redundant (TMR) technology.

A powerful, scalable design with assurance

of continuous operation, the Tricon system complies with international safety

standards such as IEC61508 and fulfils the requirements for applications such as

Emergency Shutdown (ESD), Fire and Gas Protection (F&G), Burner Management

(BMS), High Integrity Pressure Protection (HIPPS) and Turbomachinery Control

(TMC). The redundant high availability architecture provides a flexible, robust,

reliable and powerful solution that is ideal for clients looking to achieve

environmental and safety excellence.

The Tricon system is a must for clients who need to maximize the safety and

performance of their assets. If you are challenged with reducing investment and

lifecycle costs, meeting new safety standards, combating tough competitive

pressure in your markets as well as the welfare of your employees and the

environment, then the Tricon system is designed for you.

Managing operational risks with confidence

IDEC PF3S-PSA2
IDEC PF3S-T32K
IDEC PFJ-T081U
IDEC RU4S-D24
IDEC SY4S-05D
IDER ABW140EG
IMI CCI C330
IMS MX-CS101-701
IMS MX-CS101-701-G1
INDRAMAT 109-0943-3801-05
INDRAMAT 109-0943-4A03-02
INDRAMAT 109-0943-4A19-00

The Tricon fail-safe and fault-tolerant controller is used extensively in high-hazard industries

where safe operations are critical and reliable operation is paramount.

In particular, the Tricon system is the only commercial off-the-shelf controller approved by

the Nuclear Regulatory Commission for Nuclear 1E applications.

Our safety and critical control solutions are supported by a dedicated team of TÜV-certified FunctionalSafety Experts and Engineers,

deplo yed globally, ensuring that expertise is always available where and when required.

A powerful, scalable design with assurance of continuous operation,

the Tricon system complies with international standards such as IEC61508 and fulfills

the requirements for applications such as Emergency Shutdown (ESD), Fire and Gas Protection (F&G),

Burner Management (BMS),High Integrity Pressure Protection (HIPPS), and Turbo Machinery Control (TMC).

The redundant high-availability architecture provides a flexible,robust, reliable,

and powerful solution that is ideal for clients looking to achieve environmental and safety excellence.

Tricon Key capabilities

• TÜV-certified for SIL3 applications to international standard IEC61508

• High-availability architecture for continuous operation

• Fault-tolerant architecture for continuous operation even under fault conditions

• Choice of form factors

• Online module replacement ensures continuous operation and plant availability

• Online upgrade without process interruption

• Direct Integration with Foxboro®Evo process automation system

• Easily integrated with all major distributed control systems

• ISA Secure EDSA Level 1 right out of the box

• Works in both centralized and distributed applications

• HART protocol pass through to Asset Management Systems

• Fast program cycle time from 10 mS

• 1 mS SOE Digital Input

• Choice of termination options — Direct and ETP

• Expertise available from our TÜV-certified Functional Safety Experts and Engineers

• Continually current technology

• Comprehensive family of I/O modules