Triconex 3706A Thermocouple Analog Input

Fault and Alarm Indicators

Fault indicators identify potentially serious problems with a module. Alarm

conditions identify abnormal field conditions such as loss of power and loss of communication.

If a fault or alarm indicator is on, you should consult the appropriate section of this

chapter and take appropriate action. This action may include replacing a faulty

module or repairing a faulty circuit or device.

Identifying Fault and Alarm Conditions

You can identify alarm and fault conditions in the following ways:

• By examining the indicators on the front panel of each module and consulting this chapter.

• By using the Diagnostic Panel in the TriStation application.

For more information, see the TriStation 1131 Developer’s Guide.

EcoStruxure™ Triconex® – Tricon CX

EcoStruxure™ Triconex Safety System – superior protection for people, production and profits

We understand that you need more from your safety instrumented systems than just keeping your operations safe

you need to keep operations running continuously, avoiding any unexpected downtime or interruption that impacts profitability.

EcoStruxure Triconex – Tricon CX is the most powerful safety system from Triconex.

Leveraging the pedigree of the field-proven Tricon, Trident and Tri-GP systems,

Tricon CX is the best possible choice when safety and profitability are critical success factors.

The Tricon system is a must for clients who need to maximize the safety and

performance of their assets. If you are challenged with reducing investment and

lifecycle costs, meeting new safety standards, combating tough competitive

pressure in your markets as well as the welfare of your employees and the

environment, then the Tricon system is designed for you.

A powerful, scalable design with assurance

of continuous operation, the Tricon system complies with international safety

standards such as IEC61508 and fulfils the requirements for applications such as

Emergency Shutdown (ESD), Fire and Gas Protection (F&G), Burner Management

(BMS), High Integrity Pressure Protection (HIPPS) and Turbomachinery Control

(TMC). The redundant high availability architecture provides a flexible, robust,

reliable and powerful solution that is ideal for clients looking to achieve

environmental and safety excellence.

Overview

GE MVC3003-4025
GE MVS3000-4001
GE MAE99-04-COM30
GE EmETX-i701
GE PIB201A
GE P110-6052
GE RS-FS-9001-1
ABB 3BHE024577R0101
Alstom EPIC III EP3-E-4-EN
Rolls Royce R02TCN-E0L3-00
ABB RET615E_E HBTCBABAABCBC6BBN1XE
ABB P8451
ABB P8403
ABB SPHSS13
GE DS200ADMAH1AA
GE DS200SNPAH1AB
GE DS3800NHVL
GE DS200FCGDH1ABA
GE UR-9WH
GE XD1-G11
WOODWARD 8440-1935

Indicators are lights on the front panel of each module that identify the state of each module.

Each module includes indicators that identify the general state of the module and other indicators related to the function of the module.

The types of indicators include:

• Status indicators which identify the processing state of the module.

Each module includes a Pass, Fault, and Active indicator.

• A lock indicator which identifies whether the module is unlocked.

• Mode indicators which identify the current operating state of the controller.

(Only on MP Modules.)

• Field power and power load indicators which identify whether a power

problem has occurred. (Only on some I⁄O modules.)

• Communication indicators which identify the type of communication occurring.

(Only on MP and CM Modules.)

• Points indicators which identify whether the point is energized.

• Alarm indicators which identify alarm conditions for the controller.

(Only on MP Modules.)