Triconex

Digital Output Module Triconex 3603T

The Tricon system is a powerful, scalable design that ensures continuous operation,

complies with international safety standards such as IEC61508. and meets the

requirements for emergency shutdown (ESD), fire and gas protection (F&G),

burner protection (F&G) and fire safety.

It also meets the requirements of applications such as Emergency Shutdown (ESD),

Fire and Gas Protection (F&G), Burner Management System (BMS),

High Integrity Pressure Protection (HIPPS) and Turbomachinery Control (TMC).

The redundant high availability architecture provides a flexible, robust, reliablea

nd powerful solution that is ideally suited for customers looking to achieve

environmental and safety excellence.

TMR Digital Input Modules

Each TMR Digital Input (DI) Module has three independent input channels

that independently process all data entered into the module.

A microprocessor on each channel scans each input point, compiles the data,

and transmits it to the main processor as required.

The input data is then voted on the main processor before being processed

to ensure the highest integrity.

ABB REM 545BG227AAA
ABB SPAZC400
ABB REF542 PLUS 1VCF752000
ABB PSM02
ABB PSM03
ABB TRM01
ABB BIO01
ABB PIO01
GE IS420ESWBH3A TE1W031
ABB RED670 1MRK004810-KG
GE DS3800HMHA
Eaton MTL F809F-Plus
ULSTEIN PIB1039A
TRICONEX 3723X
TRICONEX 3506X
TRICONEX 3626X
ABB 1SDA104922R1

All critical signal paths are 100% triple processed to ensure safety and maximum

availability. Guaranteed safety and maximum availability.

Each channel regulates signals independently and provides optical isolation

between the field and the Tricon.

All TMR digital input modules provide complete and continuous diagnostics

for each channel.

Any diagnostic failure on any channel activates the Module Failure Indicator,

which in turn activates the chassis alarm signal.

The Module Failure Indicator points to a channel failure, not a module failure.

Modules are guaranteed to operate normally in the event of a single failure and

to continue to operate normally in the event of multiple failures of certain types.

Our strengths are the Tricon Racks, Tricon Power Modules, Main Processor Modules,

Input Modules, Output Modules, and the Tricon Communication Module TCM.

The Triconex CM3201S2 Communication Module is a highly reliable and efficient

component of the Triconex safety and control systems, specifically designed

for industrial automation and critical processes.

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注