SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT

MODEL VM-5P3 PHASE MARKER UNIT
erial interface Input signal
Hysteresis set value
(shaped waveform circuit)
(CH1)
Hysteresis set value
(shaped waveform circuit)
(CH2)
Alarm reset
system OK
Relay mode
system OK Trigger mode Tropical
spec.
3 Not provided 1 VK,RD,FK Series 0 1.0V 0 1.0V 0 AUTO-RESET 0 NORMALLY
DE-ENERGIZED
0 Auto
1 0.1V 1 0.1V 1 SELF-HOLD 1 Manual
2 0.2V 2 0.2V 1 NORMALLY
ENERGIZED
3 0.5V 3 0.5V
DIMENSION OF TARGET(Model VK,RD,FK)
CAUTION) To detect a projection(gear),provide surface A of the projection with a concentric
curve. Do not make it flat.

YOKOGAWA GC8000
IFS IFS DE7210M
EXPO ETM-IS31-001
ABB AC10272001R0101 5SXE10-0181
Kawasaki C-B10-A100-21
ABB CTI 21-P 3BDH000741R1
EPRO PR9268/600-000
HONEYWELL FC-UDI501
GEA 005-4050-710
HIMA F3237
Woodward 8237-2597
Woodward 8200-1509
triconex 3721
triconex 3503E
ALSTOM 029.359 325
ALSTOM 029.366 817
Eaton XV-102-D6-70TWRC-10
ROLLS-ROYCE 5990-PCI1022
GE MIVII1000E00HI00
GE MIFIIPA55E20HI00
Honeywell 8C-PAIHA1 51454470-275

A= mm
B= mm
C= mm
D= mm
ABNORMAL INPUT
ALARM FUNCTION
SETUP
ON(enabled) or OFF(disabled)
Preset to OFF(disabled)
(Can be changed using the internal jumper)
TRANSDUCER
POWER SUPPLY -24VDC±1V, 20mA

POWER SUPPLY OK
INDICATOR
PWR SUPPLY OK : (green LED)

SEQUENCE STATE
INDICATOR
SEQUENCE ENABLE : (yellow LED)

TRIGGER INDICATOR TRIGGER : (yellow LED)
TEMPERATURE
RANGE
Operating temperature : 0 to 65°C (32 to 149°F REF.)
Storage temperature : -30 to +85°C (-22 to +185°F REF.)
Relative humidity : 20 to 95%RH (noncondensing)
FINISH Face plate : Munsell N-4.0 (equiv.)
MASS Unit : max.0.6kg (max.1.4lb REF.)
Standard Specifications OTHER
POWER SUPPLY Supplied from instrument rack (VM-5H or VM-5W)
PHASE MARKER
SIGNAL
Phase marker : 2ch Max.
Input impedance : Approx.10kΩ
INPUT VOLTAGE 0 to 25VDC
BUFFER OUTPUT Phase marker signal : 2ch
Output voltage : -1 to –20VDC
Output impedance : 50Ω
PULSE OUTPUT Shaped pulse signal is output via a buffer amplifier.
Signal level : -1 to +1V(PL), 4 to 6V(PH)
Output impedance : 50Ω
Note) Model VM-5P3 Phase marker unit can be installed on 1 unit(VM-5P3)/1 rack(VM-5H or VM-5W
Instrument Rack), can not be installed on Model VM-5G Single Unit Instrument Rack.
The system OK alarm contacts on the instrument rack are not functional unless the VM-5P3 is mounted.
Alarm contact operation
Monitor alarm relay mode Monitor power OFF Monitor power ON
Normal state Alarm state
NO contact NORMALLY DE-ENERGIZED OPEN OPEN CLOSE
NO contact NORMALLY ENERGIZED OPEN CLOSE OPEN
NC contact NORMALLY DE-ENERGIZED CLOSE CLOSE OPEN
NC contact NORMALLY ENERGIZED CLOSE OPEN CLOSE