Shinkawa

SHINKAWA MODEL VM-5E DUAL CASE  

MODEL VM-5E DUAL CASE
EXPANSION MONITOR
Monitor range Input signal Frequency
response Polarity
*1 Operation method Recorder output Alarm reset
(DANGER)
Alarm reset
(ALERT)
Alarm reset
(OK)
1 0 to 25mm 1 VM-21 or VM-11P-20S2 0 DC to 0.5Hz 1 Direct 1 Differential 0 4 to 20mADC 0 AUTO RESET 0 AUTO RESET 0 AUTO RESET
2 0 to 50mm 2 VM-21 or VM-11P-21S2   2 Reverse 2 Direct 1 1 to 5VDC 1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD
3 0 to 100mm 3 VM-21 or VM-11P-22S2       2
Output card
/IS or /RE
option

4 0 to 1inch 4 VM-21 or VM-11P-23S2
5 0 to 2inch 5 VM-21 or VM-11P-24S2
6 0 to 4inch

Relay mode
(DANGER)
Relay mode
(ALERT)
Relay mode
(OK)
Alarm delay time
(DANGER)
Alarm delay time
(ALERT) Alarm output type First output*2
0 NORMARY
DE-ENERGIZED 0 NORMARY
DE-ENERGIZED 0 NORMARY
DE-ENERGIZED
0 3 sec. 0 3 sec. In case of differential operation 0 OFF
1 1 sec. 1 1 sec. 1 CH1 : 2 points (DANGER1,ALERT1)
H,L are OR output
1 ON
1 NORMALLY
ENERGIZED 1 NORMALLY
ENERGIZED 1 NORMALLY
ENERGIZED
2 6 sec. 2 6 sec.
3 None 3 None 2 CH1 : 4 points (H-DANGER,H-ALERT,
L-ALERT,L-DANGER)

In case of direct operation

3
CH1 : 2 points (DANGER1,ALERT1)
H,L are OR output
CH2 : 2 points (DANGER2,ALERT2)
H,L are OR output

4
CH1 : 4 points (H-DANGER,H-ALERT,
L-ALERT,L-DANGER)
CH2 : None

ABB DSAO120 5FSE707630-71
Rolls-Royce 98H010A00001
moog G771K202
GE IS420UCSBH4A Rev.I
GE IS420UCSBH1A Rev.H
ABB EL3020 3.345558.2 0241398794/0300
Magnos 206 O2 98-100%
ABB EL3020 3.346806.2 0241398794/1500
Caldos 27 Ar 0-100%
ABB AX410/50001
Foxboro FBM217
Foxboro FBM201 P0914SQ
Foxboro FBM237 P0914XS
Foxboro FBM203 RH914SV
Foxboro FBM201TA P0916AA
Foxboro FBM237TA P0916CC
Foxboro FBM203TA PO916AE
Foxboro P0916DE
ABB 3BHE057901R0101 PCD235C101
Triconex 3704E
Triconex 3504E
Triconex 3504E

ALARM SET VALUE * H-DANGER1 :
* H-ALERT1 :
* L-ALERT1 :
* L-DANGER1 :
H-DANGER2 :
H-ALERT2 :
L-ALERT2 :
L-DANGER2 :
Only * are set in case of differential operation
Unless specified otherwise, preset to :
H-DANGER : 100% of monitor range
H-ALERT : 90% of monitor range
L-ALERT : 10% of monitor range
L-DANGER : 0% of monitor range
MEASURED VALUE LCD digital meter with 5 digits
(7 segments, with back light)
LCD bar graph meter (40 segments, with back light)
* Measurement value and alarm set value are indicated on
the digital meter and bar graph meter simultaneously.
ALARM INDICATOR DANGER : (red LED)
ALERT : (yellow LED)
ABNOR. ALARM
INDICATOR
OK : (green LED)

BYPASS INDICATOR BYPASS : (red LED)
TRANSDUCER INPUT VM-11P,VM-21P
Number of input points  :  2 points
INPUT IMPEDANCE Approx. 250Ω
EXTERNAL CONTACT
INPUT
(FROM REAR PANEL)
Contact type : Dry contact
Contact for external reset
Standard Specifications
ALARM SET POINT 8 points (H-DANGER1,H-ALERT1,L-ALERT1,L-DANGER1,
H-DANGER2,H-ALERT2,L-ALERT2,L-DANGER2)
In case of differential operation,
4 points (H-DANGER,H-ALERT,L-DANGER,L-ALERT)
BAR GRAPH METER Recorder output conversion acuracy  ± 2.5% of F.S.
ZERO SHIFT 0 to 100% of monitor range
DIGITAL METER Recorder output conversion acuracy  ± 1.0% of F.S.
RECORDER OUTPUT
CONVERSION
ACCURACY
± 0.5% of F.S. at 25°C
± 2.0% of F.S. at 0 to 65°C

ALARM SET RANGE -10 to +110% of monitor range
ALARM SET
ACCURACY
± 1.0% of F.S. or less
RECORDER OUTPUT
(FROM REAR PANEL)
Voltage or current output proportional to monitor range
1 to 5VDC (output impedance : 250Ω)
4 to 20mADC (max. load resistance : 500Ω)
0 to -10VDC*,0 to 10VDC*,0 to -5VDC*,0 to 5VDC*
(output impedance : 100Ω) (*option)
Number of output points  :  2 points
When operation method is differential : 1 point
ALARM SET
REPEATABILITY
± 0.1% of F.S. or less

ALARM OUTPUT 5 points (DANGER1,ALERT1,DANGER2,ALERT2,OK) or
6 points (DANGER1,ALERT1,DANGER2,ALERT2,OK1,OK2)
In case of differential operation.
3 points (DANGER,ALERT,OK) or
4 points (DANGER,ALERT,OK1,OK2) (H,L are OR output)
(6 points when 4-point alarm is selected for CH1) MONITOR OUTPUT
(FROM FRONT,REAR
PANEL)
Input signal is output via a buffer amplifier.
Signal level : 1 to 5VDC
Output impedance : 100Ω (load resistance 50k or more) OTHERS

TEMPERATURE
RANGE
Operating temperature : 0 to 65°C (32 to 149°F)
Storage temperature : -30 to +85°C (-22 to +185°F)
Relative humidity : 20 to 95% (noncondensing)
MATERIAL AND
FINISH
Face plate : Aluminum Munsell N-4.0 (equiv.)

MASS Monitor : max.0.7kg
(including single unit instrument rack : max.2.5kg)