SAMSUNG

SAMSUNG SSAS-PRO SPTB-AI dedicated analog input terminal board

SAMSUNG SSAS-PRO SPTB-AI is a dedicated analog input terminal board designed for precise sensor signal termination within the Samsung SSAS-Pro (Ship Automation System Pro) architecture.

Functioning as a high-integrity interface between field transmitters and SSAS-Pro analog input modules (such as SPAI-16 or SPAI-6), the SPTB-AI organizes 4–20mA current loops and 0–10V DC sensor lines.

It provides dedicated shield grounding bars and built-in signal probe points to eliminate noise interference and simplify loop testing during commissioning.

Technical Parameter List

Specification Parameter Details
Manufacturer / Series Samsung Heavy Industries / SSAS-Pro Automation Series
Model SPTB-AI (Analog Input Terminal Board)
Module Compatibility Connects directly to SPAI-16, SPAI-6, and SPRI-16 analog input modules
Terminal Clamp Type Vibration-proof screw clamp or tension spring terminals
Supported Wire Gauge 0.2 mm² to 2.5 mm² (AWG 24 to AWG 12)
Signal Compatibility 4–20mA DC, 0–20mA DC, 0–10V DC, 1–5V DC, Pt100 RTD
Shield Termination Integrated common earth bar for single-point shield grounding
Module Interconnect Multi-pin shielded ribbon or pre-fabricated harness cable
Test Access Points Front-facing multimeter test points per channel

Product Features & Core Advantages

Noise-Immune Signal Termination: Built with dedicated cable shield clamps and single-point grounding paths to protect sensitive analog signals from heavy electromagnetic noise in marine engine rooms.

Streamlined Signal Testing: Integrated probe access points allow technicians to measure loop currents (4–20mA) or voltages directly at the terminal strip without opening signal circuits.

High-Retention Clamping: Engineered to maintain secure electrical contact under continuous high-vibration conditions typical of vessel operations.

Modular Interface Design: Standardized cable connectors enable rapid plug-and-play linkage to SSAS-Pro SPAI input cards, minimizing panel assembly time and wiring mistakes.

Model Classification

SSAS-Pro Terminal Board Series:

SPTB-AI: Terminal Board for Analog Input Modules (SPAI / SPRI Series)

SPTB-AO: Terminal Board for Analog Output Modules (SPAO Series)

SPTB-DI: Terminal Board for Digital Input Modules (SPDI Series)

SPTB-DO: Terminal Board for Digital Output Modules (SPDO / SPRDO Series)

Environmental Tolerance Conditions

Operating Temperature: -15°C to +55°C

Storage Temperature: -25°C to +70°C

Relative Humidity: 5% to 95% (non-condensing)

Vibration & Marine Compliance: Certified to major classification society standards (DNV, ABS, LR, KR, NK) for severe maritime engine room conditions.

Installation Method

DIN Rail Attachment: Snap the SPTB-AI base securely onto a standard 35mm DIN rail inside the instrument cabinet.

Interconnect Harness Connection: Plug the dedicated shielded multi-pin cable from the SPTB-AI terminal board into the target SPAI-16 or SPAI-6 analog input card slot.

Field Transmitter Termination: Strip transmitter cable ends (approx. 7–8 mm) and secure positive, negative, and loop power lines into the designated channel terminals.

Shield Grounding: Connect field cable braided shields directly to the SPTB-AI ground bar to prevent ground loop currents and ambient noise coupling.

Operating Instructions

Loop Power Verification: Check field loop power voltage (24V DC) and channel polarity before energizing sensor transmitters.

Current Loop Measurement: Utilize built-in test points to verify 4–20mA signal levels during zero and span transmitter calibration.

Routine Maintenance: Periodically check terminal screw tightness and inspect shield ground bars for oxidation or loose connections during scheduled vessel maintenance.